A Method for Analyzing the Damage Location of a Low-Noise Amplifier Based on High-Power Microwave Injection
IEEE Transactions on Electron Devices · 2026-07 · 73 (7) · 4331-4340
DOI: 10.1109/ted.2026.3695503 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Electron Devices, 2026-07. Verfasst von Jin Wang und 6 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Suzhou Industrial Park High Energy Innovation Platform.
Abstract (Originalsprache)
This article proposes a cross-scale analysis method for locating the damage of low-noise amplifiers (LNAs) under wide pulsewidth high-power microwave (HPM) action. In response to the inherent defect of the traditional offline S-parameter cyclic testing, which has low efficiency, this article constructs a threshold rapid criterion based on real-time voltage response monitoring, significantly improving the timeliness and repeatability of identifying the damage initiation point. In view of the deficiency that existing simulations are mostly limited to using TCAD to simulate the lattice temperature of the device, which makes it difficult to reflect the real failure behavior of the packaging structure under the action of multiple physical fields, this article establishes a TCAD–COMSOL collaborative simulation. Finally, by characterizing the micro-area morphology of the damaged samples, the failure location is confirmed. The spatial distribution, damage mode, and evolution path predicted by the simulation are highly consistent with those confirmed by the actual measurement, verifying the comprehensive advantages of this method in terms of mechanism interpretability, positioning accuracy, and engineering reproducibility.
Förderung
- Suzhou Industrial Park High Energy Innovation Platform
Zitieren
APA
Wang, J., Wang, G., Li, M., Jin, Y., Ren, J., Zhou, Z., & Tang, S. (2026). A Method for Analyzing the Damage Location of a Low-Noise Amplifier Based on High-Power Microwave Injection. IEEE Transactions on Electron Devices, 73(7), 4331-4340. https://doi.org/10.1109/ted.2026.3695503
Vancouver
Wang J, Wang G, Li M, Jin Y, Ren J, Zhou Z, et al. A Method for Analyzing the Damage Location of a Low-Noise Amplifier Based on High-Power Microwave Injection. IEEE Transactions on Electron Devices. 2026;73(7):4331-4340. doi:10.1109/ted.2026.3695503
BibTeX
@article{Wang2026,
author = {Wang, Jin and Wang, Guihua and Li, Minjie and Jin, Yinxiang and Ren, Jinjing and Zhou, Zhongyuan and Tang, Shiping},
title = {A Method for Analyzing the Damage Location of a Low-Noise Amplifier Based on High-Power Microwave Injection},
journal = {IEEE Transactions on Electron Devices},
year = {2026},
volume = {73},
number = {7},
pages = {4331--4340},
doi = {10.1109/ted.2026.3695503}
}