A Microfluidic Dual-Angle Light-Scattering Sensor for Real-Time Detection and Classification of Airborne Spores
IEEE Transactions on Electron Devices · 2026-07 · 73 (7) · 4169-4179
DOI: 10.1109/ted.2026.3689514 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Electron Devices, 2026-07. Verfasst von Ning Yang und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program Young Scientist Project, Jiangsu Provincial Department of Science and Technology.
Abstract (Originalsprache)
Airborne crop diseases caused by fungal spores pose a serious threat to agricultural productivity because of their rapid diffusion and low environmental concentration. However, most existing spore detection methods still suffer from limited sensitivity, insufficient real-time capability, or poor suitability for field deployment. This article presents a compact and low-cost airborne spore detection sensor by integrating microfluidic sheath-flow focusing with bidirectional light-scattering measurement. Within the microfluidic channel, particles are hydrodynamically confined near the centerline, providing stable conditions for single-particle optical interrogation. Forward- and side-scattering signals are synchronously acquired based on Mie scattering, and multidimensional time-domain statistical features are extracted to characterize the complementary size- and structure-related responses of different particle types. To enhance discriminative learning under limited sample conditions, a dual-scattering cross-category feature-enhanced network (DS-CCFE-Net) is developed for particle classification. The proposed model decomposes the multiclass task into parallel one-versus-rest subproblems, learns class-sensitive embeddings through branch-wise feature extraction, and performs final identification through embedding fusion and global classification. Experimental results show that the optimized sheath-flow configuration compresses the particle stream to approximately $40~\mu $ m, providing favorable optical interrogation conditions. Experiments verify a stable linear relationship between forward-scattering peak amplitude and particle size, with an R2 value of 0.96665. Across four particle categories, the proposed DS-CCFE-Net achieves an overall classification accuracy of 97.62%. These results demonstrate that the proposed sensor provides an effective and practical solution for real-time and field-deployable monitoring of airborne crop pathogen spores.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program Young Scientist Project
- Jiangsu Provincial Department of Science and Technology
Zitieren
APA
Yang, N., Xiao, L., Wang, Y., Zhang, Z., Yu, N., Liu, H., & Chen, S. (2026). A Microfluidic Dual-Angle Light-Scattering Sensor for Real-Time Detection and Classification of Airborne Spores. IEEE Transactions on Electron Devices, 73(7), 4169-4179. https://doi.org/10.1109/ted.2026.3689514
Vancouver
Yang N, Xiao L, Wang Y, Zhang Z, Yu N, Liu H, et al. A Microfluidic Dual-Angle Light-Scattering Sensor for Real-Time Detection and Classification of Airborne Spores. IEEE Transactions on Electron Devices. 2026;73(7):4169-4179. doi:10.1109/ted.2026.3689514
BibTeX
@article{Yang2026,
author = {Yang, Ning and Xiao, Lu and Wang, Yanfei and Zhang, Zhaoyuan and Yu, Ni and Liu, Haodong and Chen, Si},
title = {A Microfluidic Dual-Angle Light-Scattering Sensor for Real-Time Detection and Classification of Airborne Spores},
journal = {IEEE Transactions on Electron Devices},
year = {2026},
volume = {73},
number = {7},
pages = {4169--4179},
doi = {10.1109/ted.2026.3689514}
}
EUVIMED