Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Dielectrics and Electrical Insulation, 2026-08. Verfasst von Oscar Henry Arroyo-Fernandez und 4 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The moisture equilibrium curves between paper and oil in power transformers, originally developed by Oommen, are widely used to assess transformer insulation conditions. Oommen’s model is based on experimental data from Jeffries, in which wood pulp samples are conditioned at relative humidity levels above 5%. This study presents experimental results on the water content of insulation papers under low relative humidity conditions (1%–5%). Kraft, thermally upgraded Kraft (TUK), and aramid papers are conditioned using a glove box and environmental chamber, and the moisture content is quantified via Karl Fischer titration. The influence of nitrogen content in TUK papers on moisture sorption IS examined, revealing that nitrogenous additives reduce water uptake, likely due to the formation of nitrogenous bases. Among the tested materials, aramid paper exhibits the lowest water absorption. Equilibrium curves are generated and compared with the Jeffries-based model, showing differences in both moisture content and bubble inception temperature (BIT). The findings of this study contribute to more accurate modeling of moisture equilibrium under low-humidity conditions and facilitate the development of more robust and predictive tools for transformer insulation monitoring.

Zitieren

APA

Arroyo-Fernandez, O. H., Picher, P., Rodriguez-Celis, E. M., Morin, B., & Jalbert, J. (2026). Rebuild of Moisture Equilibrium Curves for Transformer Cellulose Insulation Immersed in Oil: Influence of Nitrogen Content in TUK Papers and Comparison With Aramid-Based Paper. IEEE Transactions on Dielectrics and Electrical Insulation, 33(4), 2996-3004. https://doi.org/10.1109/tdei.2026.3703373

Vancouver

Arroyo-Fernandez OH, Picher P, Rodriguez-Celis EM, Morin B, Jalbert J. Rebuild of Moisture Equilibrium Curves for Transformer Cellulose Insulation Immersed in Oil: Influence of Nitrogen Content in TUK Papers and Comparison With Aramid-Based Paper. IEEE Transactions on Dielectrics and Electrical Insulation. 2026;33(4):2996-3004. doi:10.1109/tdei.2026.3703373

BibTeX
@article{ArroyoFernandez2026,
  author = {Arroyo-Fernandez, Oscar Henry and Picher, Patrick and Rodriguez-Celis, Esperanza Mariela and Morin, Brigitte and Jalbert, Jocelyn},
  title = {Rebuild of Moisture Equilibrium Curves for Transformer Cellulose Insulation Immersed in Oil: Influence of Nitrogen Content in TUK Papers and Comparison With Aramid-Based Paper},
  journal = {IEEE Transactions on Dielectrics and Electrical Insulation},
  year = {2026},
  volume = {33},
  number = {4},
  pages = {2996--3004},
  doi = {10.1109/tdei.2026.3703373}
}
Kostenlos starten →