EUVIMEDEUVIMED entdecken
Crossref

Electric Field Analysis of a DC Bushing: Effects of the Anisotropic Bulk Conductivity of Epoxy Resin-Impregnated Paper

Nengfeng Guo, Haorui Xue, Bohan Lan, Wenhao Gao, Xia Wang, Weidong Ding

IEEE Transactions on Dielectrics and Electrical Insulation · 2026-06 · 33 (3) · 2118-2126

DOI: 10.1109/tdei.2025.3623955 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Dielectrics and Electrical Insulation, 2026-06. Verfasst von Nengfeng Guo und 5 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: State Grid Corporation of China Headquarters through the Science and Technology Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The valve-side bushing of the converter transformer used in ultrahigh voltage direct current (UHVdc) systems is an important component of dc transmission networks, where the operational reliability of the bushing fundamentally determines system-level safety performance. However, research on bushings rarely considers the anisotropic bulk conductivity of epoxy resin-impregnated paper (RIP). Accordingly, this study systematically characterizes the anisotropic bulk conductivity and temperature-dependent behavior of the RIP composites. A transient multiphysics simulation of electric-thermal-fluid coupling is carried out, with anisotropic bulk conductivity parameters established for the valve-side bushing of a ±800 kV converter transformer. The numerical results indicate that anisotropic bulk conductivity induces bipolar charge segregation: The epoxy core’s outer surface exposed to SF6 gas maintains positive charge accumulation, while the air gap and arc-corner surfaces develop negative charge densities of up to –14.82 pC/mm2. Under isotropic bulk conductivity, the air gap termination region maintains a uniform electric field below 0.1 kV/mm. In contrast, anisotropic bulk conductivity induces field distortions characterized by tangential/normal components reaching 0.5/1.8 kV/mm. These distortions elevate the risk of surface flashover on the bushing because of air gap discharge.

Förderung

  • State Grid Corporation of China Headquarters through the Science and Technology Project

Zitieren

APA

Guo, N., Xue, H., Lan, B., Gao, W., Wang, X., & Ding, W. (2026). Electric Field Analysis of a DC Bushing: Effects of the Anisotropic Bulk Conductivity of Epoxy Resin-Impregnated Paper. IEEE Transactions on Dielectrics and Electrical Insulation, 33(3), 2118-2126. https://doi.org/10.1109/tdei.2025.3623955

Vancouver

Guo N, Xue H, Lan B, Gao W, Wang X, Ding W. Electric Field Analysis of a DC Bushing: Effects of the Anisotropic Bulk Conductivity of Epoxy Resin-Impregnated Paper. IEEE Transactions on Dielectrics and Electrical Insulation. 2026;33(3):2118-2126. doi:10.1109/tdei.2025.3623955

BibTeX
@article{Guo2026,
  author = {Guo, Nengfeng and Xue, Haorui and Lan, Bohan and Gao, Wenhao and Wang, Xia and Ding, Weidong},
  title = {Electric Field Analysis of a DC Bushing: Effects of the Anisotropic Bulk Conductivity of Epoxy Resin-Impregnated Paper},
  journal = {IEEE Transactions on Dielectrics and Electrical Insulation},
  year = {2026},
  volume = {33},
  number = {3},
  pages = {2118--2126},
  doi = {10.1109/tdei.2025.3623955}
}
Kostenlos starten →