A ±50-A Shunt-Based Current Sensor With ±0.2% Gain Error From --40 °C to 125 °C
IEEE Transactions on Circuits and Systems I: Regular Papers · 2026-11 · 73 (11) · 7717-7728
DOI: 10.1109/tcsi.2026.3716985 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Circuits and Systems I: Regular Papers, 2026-11. Verfasst von Seong-Bo Park und 8 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: IC Design Education Center of Korea Advanced Institute of Science and Technology, BK21Plus Program funded by the Ministry of Education, South Korea, National Research Foundation of Korea.
Abstract (Originalsprache)
This paper presents a shunt-based low-side current sensor that consists of an off-chip PCB trace shunt resistor and a readout circuit. A temperature-dependent reference voltage, composed of a proportional-to-absolute-temperature voltage and a tunable complementary-to-absolute-temperature (CTAT) voltage, is used to compensate for the shunt’s temperature-dependent resistance variation. To compensate for both the first- and higher-order temperature dependence of the shunt resistor, this paper proposes a CTAT voltage generation technique based on a temperature-coefficient (TC)-adjustable current source and a CTAT resistor. This technique enables the shunt’s temperature-dependent resistance variation to be compensated over a wide temperature range using only a single batch-calibration parameter. In addition, this paper proposes a dual-mode amplifier for the first integrator of the discrete-time $\Delta \Sigma $ ADC-based readout circuit to improve power efficiency and reduce sensitivity to PVT variation. The current sensor was fabricated in a 0.18- $\mu $ m CMOS process occupying 0.43 mm 2 and consumes $374~\mu $ W from a 1.8-V supply. Over the automotive temperature range ( $- 40~^{\circ }$ C to $125~^{\circ }$ C) and for currents up to ±50 A, it achieves a gain error of ±0.2% after a one-point gain trim at room temperature.
Förderung
- IC Design Education Center of Korea Advanced Institute of Science and Technology
- BK21Plus Program funded by the Ministry of Education, South Korea
- National Research Foundation of Korea
Zitieren
APA
Park, S., Kim, H., Lee, J., Choi, S., Kim, T., Yim, J., Boo, J., Moon, U., & Ahn, G. (2026). A ±50-A Shunt-Based Current Sensor With ±0.2% Gain Error From --40 °C to 125 °C. IEEE Transactions on Circuits and Systems I: Regular Papers, 73(11), 7717-7728. https://doi.org/10.1109/tcsi.2026.3716985
Vancouver
Park S, Kim H, Lee J, Choi S, Kim T, Yim J, et al. A ±50-A Shunt-Based Current Sensor With ±0.2% Gain Error From --40 °C to 125 °C. IEEE Transactions on Circuits and Systems I: Regular Papers. 2026;73(11):7717-7728. doi:10.1109/tcsi.2026.3716985
BibTeX
@article{Park2026,
author = {Park, Seong-Bo and Kim, Hyoung-Jung and Lee, Jae-Hyuk and Choi, Seong-U and Kim, Tae-Heon and Yim, Jun-Young and Boo, Jun-Ho and Moon, Un-Ku and Ahn, Gil-Cho},
title = {A ±50-A Shunt-Based Current Sensor With ±0.2% Gain Error From --40 °C to 125 °C},
journal = {IEEE Transactions on Circuits and Systems I: Regular Papers},
year = {2026},
volume = {73},
number = {11},
pages = {7717--7728},
doi = {10.1109/tcsi.2026.3716985}
}
EUVIMED