A Current-Balanced Analog Frontend System With Adaptive Input Voltage for Multiple Cell Li-ion Battery Electrochemical Impedance Monitoring
IEEE Transactions on Circuits and Systems I: Regular Papers · 2026-11 · 73 (11) · 7852-7863
DOI: 10.1109/tcsi.2026.3703047 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Circuits and Systems I: Regular Papers, 2026-11. Verfasst von Yutong Zhang und 7 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Jianbing Research and Development Project of Zhejiang Province.
Abstract (Originalsprache)
This paper presents a battery management frontend ASIC for DC voltage and electrochemical impedance spectroscopy (EIS) recordings, which can provide more accurate and real-time estimation of state of charge and temperature of Li-ion battery cells. In order to accurately acquire DC and EIS signals, two separate voltage readout channels and a current channel are deployed. The voltage channel instrumentation amplifier is high-voltage (HV)-powered (HVIA) and can be shared between channels, saving power and area, while a DC-servo loop (DSL) helps to improve the effective dynamic range for EIS at the channel output. Moreover, two SAR ADCs are used for the voltage and current channels. On circuit level, a HV multiplexer is proposed for cell selection, including current-driven P-type and N-type HV switches, avoiding using additional voltage booster commonly required in all-N-type designs. An adaptive input common-mode (CM) voltage current-balanced topology is proposed for HVIA. This HVIA includes a transimpedance and a transconductance stage, converting the high CM voltage to low voltage, while amplifying the differential component through current. Within the EIS channel, the DC voltage is removed by a digitally-assisted DSL, accelerating the settling by exploiting the measured DC values. Fabricated in a 0.18- $\mu $ m BCD process, the chip consumes 1.9mA during operation. It achieves EIS measurement from 5Hz to 5kHz with 0.8m $\Omega $ resolution and support DC voltage measurement with an error of less than 5mV, advancing the state-of-the-art.
Förderung
- Jianbing Research and Development Project of Zhejiang Province
Zitieren
APA
Zhang, Y., Zhang, Y., Chen, C., Wang, D., Jiang, X., Zhang, Y., Huang, K., & Song, S. (2026). A Current-Balanced Analog Frontend System With Adaptive Input Voltage for Multiple Cell Li-ion Battery Electrochemical Impedance Monitoring. IEEE Transactions on Circuits and Systems I: Regular Papers, 73(11), 7852-7863. https://doi.org/10.1109/tcsi.2026.3703047
Vancouver
Zhang Y, Zhang Y, Chen C, Wang D, Jiang X, Zhang Y, et al. A Current-Balanced Analog Frontend System With Adaptive Input Voltage for Multiple Cell Li-ion Battery Electrochemical Impedance Monitoring. IEEE Transactions on Circuits and Systems I: Regular Papers. 2026;73(11):7852-7863. doi:10.1109/tcsi.2026.3703047
BibTeX
@article{Zhang2026,
author = {Zhang, Yutong and Zhang, Yulu and Chen, Chen and Wang, Dehong and Jiang, Xiaowen and Zhang, Yongliang and Huang, Kai and Song, Shuang},
title = {A Current-Balanced Analog Frontend System With Adaptive Input Voltage for Multiple Cell Li-ion Battery Electrochemical Impedance Monitoring},
journal = {IEEE Transactions on Circuits and Systems I: Regular Papers},
year = {2026},
volume = {73},
number = {11},
pages = {7852--7863},
doi = {10.1109/tcsi.2026.3703047}
}
EUVIMED