Fachartikel in der Zeitschrift IEEE Transactions on Circuits and Systems I: Regular Papers, 2023-07. Verfasst von Han-Sol Lee und 9 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 72 Literaturangaben. Gefördert von: Korea Health Technology Research and Development Project, Korea Health Industry Development Institute, Ministry of Health and Welfare, South Korea.
Abstract (Originalsprache)
There is an increasing demand for real-time neural signal monitoring from a large number of electrodes to provide adequate spatial and temporal resolution for high-density brain neural interfaces. This paper proposes an adaptive multi-channel neural recording system that can record neural signals from a large number of electrodes using a smaller number of recording channels. The system utilizes an adaptive electrode selection technique to automatically scan the electrodes where neural spikes occur and record those selected electrodes. A proposed 32-electrode neural recording prototype, including 12 recording channels and 8 scanning channels, was fabricated in a 180-nm CMOS process and tested in vitro. With pre-recorded neural data, the system verified that the occurrence of neural spikes in specific electrodes could be detected and processed in real-time, enabling automatic electrode selection. Measured results showed that the proposed system could lead to over 40% reduction in silicon area compared to conventional works.
Förderung
- Korea Health Technology Research and Development Project
- Korea Health Industry Development Institute
- Ministry of Health and Welfare, South Korea
- Ministry of Trade, Industry and Energy, South Korea
Zitieren
APA
Lee, H., Eom, K., Park, M., Ku, S., Lee, K., Kim, T., Kim, T., Shon, Y., Park, H., & Lee, H. (2023). A Multi-Channel Neural Recording System With Neural Spike Scan and Adaptive Electrode Selection for High-Density Neural Interface. IEEE Transactions on Circuits and Systems I: Regular Papers, 70(7), 2844-2857. https://doi.org/10.1109/tcsi.2023.3268686
Vancouver
Lee H, Eom K, Park M, Ku S, Lee K, Kim T, et al. A Multi-Channel Neural Recording System With Neural Spike Scan and Adaptive Electrode Selection for High-Density Neural Interface. IEEE Transactions on Circuits and Systems I: Regular Papers. 2023;70(7):2844-2857. doi:10.1109/tcsi.2023.3268686
BibTeX
@article{Lee2023,
author = {Lee, Han-Sol and Eom, Kyeongho and Park, Minju and Ku, Seung-Beom and Lee, Kwonhong and Kim, Taewoo and Kim, Taekyung and Shon, Young-Min and Park, Hangue and Lee, Hyung-Min},
title = {A Multi-Channel Neural Recording System With Neural Spike Scan and Adaptive Electrode Selection for High-Density Neural Interface},
journal = {IEEE Transactions on Circuits and Systems I: Regular Papers},
year = {2023},
volume = {70},
number = {7},
pages = {2844--2857},
doi = {10.1109/tcsi.2023.3268686}
}
EUVIMED