Non-Invasive Measurement of In Vivo Corneal Steady-State Biomechanical Properties via Controllable Negative Pressure Inflation
IEEE Transactions on Biomedical Engineering · 2026-03 · 73 (3) · 1289-1297
DOI: 10.1109/tbme.2025.3603048 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2026-03. Verfasst von Zimeng Zhou und 11 weiteren Autor:innen. Hauptthemen laut MEDLINE: Cornea, Intraocular Pressure. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Postdoctoral Elite Talent Introduction Program of Hubei Province.
Abstract (Originalsprache)
OBJECTIVE: To measure the steady-state corneal biomechanical properties related to postoperative corneal ectasia, keratoconus, glaucoma and other ophthalmic diseases, we propose a novel in vivo measurement method. METHODS: By precisely manipulating ambient negative pressure via a suction device to achieve controlled in vivo corneal inflation, we analyzed the coupling relationship between corneal deformation response and negative pressure loading. The displacement corresponding to the corneal initial configuration under 0 mmHg was extrapolated. The inverse finite element analysis (FEA) technique was employed to calculate the segmental Young's modulus of the cornea under different steady-state intraocular pressure (IOP) conditions. RESULTS: In vivo experiments on 3-month-old rabbit eyes demonstrated a Young's modulus of 0.2-0.3 MPa at physiological IOP (10-12 mmHg), along with an increasing trend of corneal stiffness across a pressure range of 0-85 mmHg. CONCLUSION: The proposed non-invasive measurement method exhibits stability and consistency in parameter inversion under different IOPs, indicating its significant clinical potential. SIGNIFICANCE: Providing a new approach for corneal biomechanical assessment is beneficial for the diagnosis and treatment of ophthalmic diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
- Postdoctoral Elite Talent Introduction Program of Hubei Province
Zitieren
APA
Zhou, Z., Wang, H., Wang, Z., Zhang, Y., Lv, H., Zhang, Z., Gao, Z., Liu, X., Lv, X., Quan, T., Chen, S., & Zeng, S. (2026). Non-Invasive Measurement of In Vivo Corneal Steady-State Biomechanical Properties via Controllable Negative Pressure Inflation. IEEE Transactions on Biomedical Engineering, 73(3), 1289-1297. https://doi.org/10.1109/tbme.2025.3603048
Vancouver
Zhou Z, Wang H, Wang Z, Zhang Y, Lv H, Zhang Z, et al. Non-Invasive Measurement of In Vivo Corneal Steady-State Biomechanical Properties via Controllable Negative Pressure Inflation. IEEE Transactions on Biomedical Engineering. 2026;73(3):1289-1297. doi:10.1109/tbme.2025.3603048
BibTeX
@article{Zhou2026,
author = {Zhou, Zimeng and Wang, Honghao and Wang, Zuowei and Zhang, Ying and Lv, Haijun and Zhang, Zhuoyu and Gao, Zhengwen and Liu, Xiuli and Lv, Xiaohua and Quan, Tingwei and Chen, Shangbin and Zeng, Shaoqun},
title = {Non-Invasive Measurement of In Vivo Corneal Steady-State Biomechanical Properties via Controllable Negative Pressure Inflation},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2026},
volume = {73},
number = {3},
pages = {1289--1297},
doi = {10.1109/tbme.2025.3603048}
}
EUVIMED