EUVIMEDEUVIMED entdecken
Crossref

3D Transcranial Dynamic Ultrasound Localization Microscopy in the Mouse Brain Using a Row-Column Array

Alice Wu, Jonathan Poree, Gerardo Ramos-Palacios, Nin Ghigo, Chloe Bourquin, Alexis Leconte, Paul Xing, Abbas F Sadikot, Michael Chasse, Jean Provost

IEEE Transactions on Biomedical Engineering · 2026-03 · 73 (3) · 1112-1123

DOI: 10.1109/tbme.2025.3598693 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2026-03. Verfasst von Alice Wu und 9 weiteren Autor:innen. Hauptthemen laut MEDLINE: Brain, Imaging, Three-Dimensional. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 75 Literaturangaben. Gefördert von: Institut de Valorisation des Données, Canada Foundation for Innovation, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To assess the role of brain hemodynamics in neurodegenerative diseases, current imaging technologies remain insufficient due to limitations in spatial or temporal resolution for quantitative mapping of pulsatile flow in the whole brain. This study aims to demonstrate the feasibility of 3D transcranial Dynamic Ultrasound Localization Microscopy (DULM) for spatiotemporal blood flow measurements in the brain, addressing limitations of 2D imaging for velocity estimation within the 3D complex vascularized structures. METHODS: We used a (128+128)-element, 12 MHz Row-Column Array (RCA) to perform transcranial DULM imaging in anesthetized mice (n = 7 in total). The RCA setup allows for reduced element count while maintaining a large field of view and high frame rate compared to matrix arrays. Transcranial images were acquired at a 750-Hz volume rate using an optimized microbubble concentration and a sequence of 42 tilted plane waves. Microbubbles were localized and tracked, enabling super-resolved dynamic density and velocity maps of the 3D brain vascular network. RESULTS: Pulsatile flows were observed with 3D DULM in 7 mice. The segmentation of cortical vessels indicated that pulsatility in arteries was significantly higher than in veins, consistent across all mice and aligning with findings in existing literature. CONCLUSION: This study demonstrates for the first time the feasibility and reproducibility of obtaining high spatiotemporal resolution images of mouse brain vasculature using transcranial DULM with a RCA. SIGNIFICANCE: This work highlights the potential of RCA 3D DULM for non-invasive cerebral hemodynamics studies, it might enable comprehensive vascular imaging suitable for research in early-stage neurodegenerative diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainImaging, Three-DimensionalAnimalsMiceMice, Inbred C57BLCerebrovascular CirculationMaleMicrobubbles

Förderung

  • Institut de Valorisation des Données
  • Canada Foundation for Innovation
  • Canadian Institutes of Health Research
  • New Frontiers in Research Fund
  • Natural Sciences and Engineering Research Council of Canada
  • Institut TransMedTech
  • Fonds de recherche du Québec - Nature et Technologies
  • Réseau de Bio-Imagerie du Quebec

Zitieren

APA

Wu, A., Poree, J., Ramos-Palacios, G., Ghigo, N., Bourquin, C., Leconte, A., Xing, P., Sadikot, A. F., Chasse, M., & Provost, J. (2026). 3D Transcranial Dynamic Ultrasound Localization Microscopy in the Mouse Brain Using a Row-Column Array. IEEE Transactions on Biomedical Engineering, 73(3), 1112-1123. https://doi.org/10.1109/tbme.2025.3598693

Vancouver

Wu A, Poree J, Ramos-Palacios G, Ghigo N, Bourquin C, Leconte A, et al. 3D Transcranial Dynamic Ultrasound Localization Microscopy in the Mouse Brain Using a Row-Column Array. IEEE Transactions on Biomedical Engineering. 2026;73(3):1112-1123. doi:10.1109/tbme.2025.3598693

BibTeX
@article{Wu2026,
  author = {Wu, Alice and Poree, Jonathan and Ramos-Palacios, Gerardo and Ghigo, Nin and Bourquin, Chloe and Leconte, Alexis and Xing, Paul and Sadikot, Abbas F and Chasse, Michael and Provost, Jean},
  title = {3D Transcranial Dynamic Ultrasound Localization Microscopy in the Mouse Brain Using a Row-Column Array},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2026},
  volume = {73},
  number = {3},
  pages = {1112--1123},
  doi = {10.1109/tbme.2025.3598693}
}
Kostenlos starten →