Data-Centric Learning Framework for Real-Time Detection of Aiming Beam in Fluorescence Lifetime Imaging Guided Surgery
IEEE Transactions on Biomedical Engineering · 2025
DOI: 10.1109/tbme.2025.3557376 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025. Verfasst von Mohamed Abul Hassan und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Optical Imaging, Robotic Surgical Procedures, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIBIB NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
This study introduces a novel data-centric approach to improve real-time surgical guidance using fiber-based fluorescence lifetime imaging (FLIm). A key aspect of the methodology is the accurate detection of the aiming beam, which is essential for localizing points used to map FLIm measurements onto the tissue region within the surgical field. The primary challenge arises from the complex and variable conditions encountered in the surgical environment, particularly in Transoral Robotic Surgery (TORS). Uneven illumination in the surgical field can cause reflections, reduce contrast, and results in inconsistent color representation, further complicating aiming beam detection. To overcome these challenges, an instance segmentation model was developed using a data-centric training strategy that improves accuracy by minimizing label noise and enhancing detection robustness. The model was evaluated on a dataset comprising 40 in vivo surgical videos, demonstrating a median detection rate of 85%. This performance was maintained when the model was integrated in a clinical system, achieving a similar detection rate of 85% during TORS procedures conducted in patients. The system's computational efficiency, measured at approximately 24 frames per second (FPS), was sufficient for real-time surgical guidance. This study enhances the reliability of FLIm-based aiming beam detection in complex surgical environments, advancing the feasibility of real-time, image-guided interventions for improved surgical precision.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
- Intuitive Surgical
Zitieren
APA
Hassan, M. A., Sun, P., Zhou, X., Kraft, L., Hadfield, K. T., Ehrlich, K., Qi, J., Birkeland, A., & Marcu, L. (2025). Data-Centric Learning Framework for Real-Time Detection of Aiming Beam in Fluorescence Lifetime Imaging Guided Surgery. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2025.3557376
Vancouver
Hassan MA, Sun P, Zhou X, Kraft L, Hadfield KT, Ehrlich K, et al. Data-Centric Learning Framework for Real-Time Detection of Aiming Beam in Fluorescence Lifetime Imaging Guided Surgery. IEEE Transactions on Biomedical Engineering. 2025. doi:10.1109/tbme.2025.3557376
BibTeX
@article{Hassan2025,
author = {Hassan, Mohamed Abul and Sun, Pu and Zhou, Xiangnan and Kraft, Lisanne and Hadfield, Kelsey T and Ehrlich, Katjana and Qi, Jinyi and Birkeland, Andrew and Marcu, Laura},
title = {Data-Centric Learning Framework for Real-Time Detection of Aiming Beam in Fluorescence Lifetime Imaging Guided Surgery},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2025},
doi = {10.1109/tbme.2025.3557376}
}
EUVIMED