Automatic Measurement of Loop Gain Based on Pseudorandom Binary Sequence CO 2 Stimulation
IEEE Transactions on Biomedical Engineering · 2025-01 · 72 (1) · 256-263
DOI: 10.1109/tbme.2024.3449410 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2025-01. Verfasst von Yifan Qian und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Carbon Dioxide, Signal Processing, Computer-Assisted, Sleep Apnea, Obstructive. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Laboratory for Intelligent Sleep Monitoring Research, Institute for Precision Medicine, Tsinghua University.
Abstract (Originalsprache)
OBJECTIVE: Measurement of loop gain in patients with obstructive sleep apnea (OSA) is of great importance for determining the cause of OSA and realizing precision medicine. In this study, automatic measurement of loop gain is carried out during wakefulness based on the pseudorandom binary sequence (PRBS) CO2 stimulation method. METHODS: A respiratory data acquisition platform is designed and constructed to automate the processes of gas configuration, ventilatory stimulation with CO2 and data acquisition. The respiratory data are substituted into the model of the ventilatory control system for parameter identification, and the loop gain values are calculated and then compared with the apnea-hypopnea index (AHI) measured in a hypoxia chamber. RESULTS: A positive correlation is found between loop gain and AHI measured in the hypoxia chamber, with the linear correlation coefficient of approximately 0.65. CONCLUSION: The feasibility of automatic measurement of loop gain using the respiratory data acquisition platform based on the PRBS CO2 stimulation method is validated, and the measured loop gain values can be used to assess the stability of ventilatory control. SIGNIFICANCE: This study provides an automated, rapid, and instrumented solution for loop gain measurement, laying the foundation for wide-scale clinical application of the PRBS CO2 stimulation method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Laboratory for Intelligent Sleep Monitoring Research
- Institute for Precision Medicine, Tsinghua University
Zitieren
APA
Qian, Y., Tong, H., Cao, P., Yue, G., Li, J., Li, Y., & Ye, J. (2025). Automatic Measurement of Loop Gain Based on Pseudorandom Binary Sequence CO 2 Stimulation. IEEE Transactions on Biomedical Engineering, 72(1), 256-263. https://doi.org/10.1109/tbme.2024.3449410
Vancouver
Qian Y, Tong H, Cao P, Yue G, Li J, Li Y, et al. Automatic Measurement of Loop Gain Based on Pseudorandom Binary Sequence CO 2 Stimulation. IEEE Transactions on Biomedical Engineering. 2025;72(1):256-263. doi:10.1109/tbme.2024.3449410
BibTeX
@article{Qian2025,
author = {Qian, Yifan and Tong, Hao and Cao, Peiyao and Yue, Guanghao and Li, Juan and Li, Yong and Ye, Jingying},
title = {Automatic Measurement of Loop Gain Based on Pseudorandom Binary Sequence CO 2 Stimulation},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2025},
volume = {72},
number = {1},
pages = {256--263},
doi = {10.1109/tbme.2024.3449410}
}
EUVIMED