Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2024. Verfasst von Pholpat Durongbhan und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: X-Ray Microtomography, Osteophyte, Imaging, Three-Dimensional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Swiss Commission for Technology and Innovation CTI, Discovery Projects Scheme of the Australian Research Council, Christine and T Jack Martin Research Travel Grant of the Australian & New Zealand Bone & Mineral Society.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Traditional quantitative analysis of bone microstructure in micro-computed tomography (microCT) is dependent on animal scale and requires parametric tuning in new implementations. This study aims to develop an automated and resolution-invariant 3D image processing workflow for quantitative assessment of osteophytes. METHODS: In this workflow, cortical bone was segmented from microCT scans, and a 3D sphere-fitting transform was performed to obtain a thickness map, for which each voxel is assigned a thickness value corresponding to the size of the largest sphere containing the voxel that fits entirely within the cortical bone. From the thickness map, a 1-voxel thick outer surface was extracted to model surface roughness. The thickness values of the outer surface were empirically estimated by a series of known statistical distributions. Resulting parameters describing best-fit distributions, along with other cortical bone metrics, were analysed to determine sensitivity to osteoarthritis and the presence of osteophytes. RESULTS: The workflow was validated using microCT scans and histological gradings of rabbit and rat tibiofemoral joints. Visual inspection shows that samples with osteoarthritis and the presence of osteophytes have more surface voxels assigned small thickness values. The distribution of surface thickness values for each animal is best described by Gamma distributions, whose shape parameter is consistently sensitive to osteoarthritis and the presence of osteophytes. CONCLUSION: Combining traditional image processing with empirical distribution fitting provides an automated, objective, and resolution-invariant workflow for osteophyte assessment. SIGNIFICANCE: The proposed method is simple, yet elegant in its implementation, and can be readily used in new implementations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

X-Ray MicrotomographyOsteophyteImaging, Three-DimensionalAnimalsRabbitsRatsWorkflowOsteoarthritis

Förderung

  • Swiss Commission for Technology and Innovation CTI
  • Discovery Projects Scheme of the Australian Research Council
  • Christine and T Jack Martin Research Travel Grant of the Australian & New Zealand Bone & Mineral Society

Zitieren

APA

Durongbhan, P., Davey, C. E., & Stok, K. S. (2024). Empirical Modelling Workflow for Resolution Invariant Assessment of Osteophytes. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2024.3431634

Vancouver

Durongbhan P, Davey CE, Stok KS. Empirical Modelling Workflow for Resolution Invariant Assessment of Osteophytes. IEEE Transactions on Biomedical Engineering. 2024. doi:10.1109/tbme.2024.3431634

BibTeX
@article{Durongbhan2024,
  author = {Durongbhan, Pholpat and Davey, Catherine E and Stok, Kathryn S},
  title = {Empirical Modelling Workflow for Resolution Invariant Assessment of Osteophytes},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2024},
  doi = {10.1109/tbme.2024.3431634}
}
Kostenlos starten →