EUVIMEDEUVIMED entdecken
Crossref

Sticker-Type Remote Monitoring System for Early Risk Detection of Catheter Associated Urinary Tract Infections

Sarath Gopalakrishnan, Muhammad Masud Rana, Michael Anthony Curry, Akshay Krishnakumar, Rahim Rahimi

IEEE Transactions on Biomedical Engineering · 2024

DOI: 10.1109/tbme.2024.3361439 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2024. Verfasst von Sarath Gopalakrishnan und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Urinary Tract Infections, Remote Sensing Technology, Catheter-Related Infections. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Wabash Heartland Innovation Network, Scalable Manufacturing Aware and Responsive Thin Films, Birck Nanotechnology Center, Purdue University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A substantial number of critically ill patients in intensive care units (ICUs) rely on indwelling urinary catheters (IDCs), demanding regular monitoring of urine bags. This process increases the workload for healthcare providers and elevates the risk of exposure to contagious diseases. Moreover, IDCs are a primary cause of catheter-associated urinary tract infections (UTIs) in ICU patients whose delayed detection can have life-threatening complications. To address this, we have developed a Sticker Type Antenna for Remote Sensing (STARS) system capable of measuring urine flow rate and conductivity as early-risk markers for UTIs, alongside tracking patients' urine bag status to facilitate medical automation for healthcare providers. STARS comprises a simple, low-cost, disposable antenna module for contactless measurements of urine volume and conductivity, and a reusable wireless module for real-time data transmission. Systematic studies on STARS revealed its stable performance within physiologically relevant ranges of urine volume (0 to 2000 ml) and conductivity (5 to 40 mS/cm) in urine bags. As a proof-of-concept, STARS was tested in artificially created healthy and infected urine specimens to validate its non-contact sensing performance in detecting the onset of UTIs in catheterized patients within a hospital-like environment. STARS represents the first application of a real-time, contactless, wireless monitoring platform for simultaneous urine bag management and early risk detection of UTIs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary Tract InfectionsRemote Sensing TechnologyCatheter-Related InfectionsHumansEquipment DesignWireless TechnologyUrinary CathetersEarly Diagnosis

Förderung

  • Wabash Heartland Innovation Network
  • Scalable Manufacturing Aware and Responsive Thin Films
  • Birck Nanotechnology Center, Purdue University
  • School of Electrical and Computer Engineering
  • School of Materials Engineering, Purdue University
  • Purdue University

Zitieren

APA

Gopalakrishnan, S., Rana, M. M., Curry, M. A., Krishnakumar, A., & Rahimi, R. (2024). Sticker-Type Remote Monitoring System for Early Risk Detection of Catheter Associated Urinary Tract Infections. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2024.3361439

Vancouver

Gopalakrishnan S, Rana MM, Curry MA, Krishnakumar A, Rahimi R. Sticker-Type Remote Monitoring System for Early Risk Detection of Catheter Associated Urinary Tract Infections. IEEE Transactions on Biomedical Engineering. 2024. doi:10.1109/tbme.2024.3361439

BibTeX
@article{Gopalakrishnan2024,
  author = {Gopalakrishnan, Sarath and Rana, Muhammad Masud and Curry, Michael Anthony and Krishnakumar, Akshay and Rahimi, Rahim},
  title = {Sticker-Type Remote Monitoring System for Early Risk Detection of Catheter Associated Urinary Tract Infections},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2024},
  doi = {10.1109/tbme.2024.3361439}
}
Kostenlos starten →