Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2024. Verfasst von Gatha Adhikari und 10 weiteren Autor:innen. Hauptthemen laut MEDLINE: Cellulose, Phantoms, Imaging, Ethanol, Gels. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
OBJECTIVE: Local drug delivery aims to minimize systemic toxicity by preventing off-target effects; however, injection parameters influencing depot formation of injectable gels have yet to be thoroughly studied. We explored the effects of needle characteristics, injection depth, rate, volume, and polymer concentration on gel ethanol distribution in both tissue and phantoms. METHODS: The polymer ethyl cellulose (EC) was added to ethanol to form an injectable gel to ablate cervical precancer and cancer. Tissue mimicking phantoms composed of 1% agarose dissolved in deionized water were used to establish overall trends between various injection parameters and the resulting gel distribution. Additional experiments were performed in excised swine cervices with a CT-imageable injectate formulation, which enabled visualization of the distribution without tissue sectioning. RESULTS: Needle type and injection rate had minimal impact on gel distribution, while needle depths ≥13 mm yielded significantly larger distributions. Needle gauge and EC concentration impacted injection pressure with maximum gel distribution achieved when the pressure was 70-250 kPa. Injection volumes ≤3 mL of 6% EC-ethanol minimized fluid leakage away from the injection site. Results guided the development of a speculum-compatible hand-held injector to deliver gel ethanol into the cervix. CONCLUSION: Needle depth, gauge, and polymer concentration are critical to consider when delivering injectable gels. SIGNIFICANCE: This study addressed key questions related to the impact of injection-based parameters on gel distribution at a scale relevant to human applications including: 1) how best to deliver EC-ethanol into the cervix and 2) general insights about injection protocols relevant to the delivery of injectable gels in tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- NCI NIH HHS
- National Institutes of Health
Zitieren
APA
Adhikari, G., Sarojasamhita, V. P., Powell, V. R., Farooqui, A., Budzinski, M., Garvey, D. T., Yang, J., Katz, D., Crouch, B., Ramanujam, N., & Mueller, J. L. (2024). Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2023.3340613
Vancouver
Adhikari G, Sarojasamhita VP, Powell VR, Farooqui A, Budzinski M, Garvey DT, et al. Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms. IEEE Transactions on Biomedical Engineering. 2024. doi:10.1109/tbme.2023.3340613
BibTeX
@article{Adhikari2024,
author = {Adhikari, Gatha and Sarojasamhita, Venkata Polavarapu and Powell, Vene Richardson and Farooqui, Asma and Budzinski, Maya and Garvey, David T and Yang, Jeffrey and Katz, David and Crouch, Brian and Ramanujam, Nimmi and Mueller, Jenna L},
title = {Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2024},
doi = {10.1109/tbme.2023.3340613}
}