EUVIMEDEUVIMED entdecken
Open Access

Non-Invasive Pressure-Only Aortic Wave Intensity Evaluation Using Hybrid Fourier Decomposition-Machine Learning Approach

Arian Aghilinejad, Heng Wei, Niema M Pahlevan

IEEE Transactions on Biomedical Engineering · 2023

DOI: 10.1109/tbme.2023.3236918 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2023. Verfasst von Arian Aghilinejad und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Aorta, Carotid Arteries. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: American Heart Association-American Stroke Association, NHLBI NIH HHS, National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The clinical significance of the wave intensity (WI) analysis for the diagnosis and prognosis of the cardiovascular and cerebrovascular diseases is well-established. However, this method has not been fully translated into clinical practice. From practical point of view, the main limitation of WI method is the need for concurrent measurements of both pressure and flow waveforms. To overcome this limitation, we developed a Fourier-based machine learning (F-ML) approach to evaluate WI using only the pressure waveform measurement. METHODS: Tonometry recordings of the carotid pressure and ultrasound measurements for the aortic flow waveforms from the Framingham Heart Study (2640 individuals; 55% women) were used for developing the F-ML model and the blind testing. RESULTS: Method-derived estimates are significantly correlated for the first and second forward wave peak amplitudes (Wf1, r = 0.88, p 0.05; Wf2, r = 0.84, p 0.05) and the corresponding peak times (Wf1, r = 0.80, p < 0.05; Wf2, r = 0.97, p 0.05). For backward components of WI (Wb1), F-ML estimates correlated strongly for the amplitude (r = 0.71, p 0.05) and moderately for the peak time (r = 0.60, p 0.05). The results show that the pressure-only F-ML model significantly outperforms the analytical pressure-only approach based on the reservoir model. In all cases, the Bland-Altman analysis shows negligible bias in the estimations. CONCLUSION: The proposed pressure-only F-ML approach provides accurate estimates for WI parameters. SIGNIFICANCE: The pressure only F-ML approach introduced in this work expand the clinical usage of WI into inexpensive and non-invasive settings such as wearable telemedicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AortaCarotid ArteriesHumansFemaleMaleBlood PressurePulse Wave Analysis

Förderung

  • American Heart Association-American Stroke Association
  • NHLBI NIH HHS
  • National Science Foundation
  • NSF CAREER
  • Krueger Wyeth settlement case
  • Beasley Allen Law Firm
  • American Heart Association Predoctoral Fellowship awarded
  • Arian Aghilinejad

Zitieren

APA

Aghilinejad, A., Wei, H., & Pahlevan, N. M. (2023). Non-Invasive Pressure-Only Aortic Wave Intensity Evaluation Using Hybrid Fourier Decomposition-Machine Learning Approach. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2023.3236918

Vancouver

Aghilinejad A, Wei H, Pahlevan NM. Non-Invasive Pressure-Only Aortic Wave Intensity Evaluation Using Hybrid Fourier Decomposition-Machine Learning Approach. IEEE Transactions on Biomedical Engineering. 2023. doi:10.1109/tbme.2023.3236918

BibTeX
@article{Aghilinejad2023,
  author = {Aghilinejad, Arian and Wei, Heng and Pahlevan, Niema M},
  title = {Non-Invasive Pressure-Only Aortic Wave Intensity Evaluation Using Hybrid Fourier Decomposition-Machine Learning Approach},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2023},
  doi = {10.1109/tbme.2023.3236918}
}
Kostenlos starten →