EUVIMEDEUVIMED entdecken
Crossref

Approach to Quantify Eye Movements to Augment Stroke Diagnosis With a Non-Calibrated Eye-Tracker

Mohamed Abul Hassan, Chad M Aldridge, Yan Zhuang, Xuwang Yin, Timothy McMurry, Gustavo K Rohde, Andrew M Southerland

IEEE Transactions on Biomedical Engineering · 2023

DOI: 10.1109/tbme.2022.3227015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2023. Verfasst von Mohamed Abul Hassan und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Eye Movements, Stroke. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: AHA/ASA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Automated eye-tracking technology could enhance diagnosis for many neurological diseases, including stroke. Current literature focuses on gaze estimation through a form of calibration. However, patients with neuro-ocular abnormalities may have difficulty completing a calibration procedure due to inattention or other neurological deficits. OBJECTIVE: We investigated 1) the need for calibration to measure eye movement symmetry in healthy controls and 2) the potential of eye movement symmetry to distinguish between healthy controls and patients. METHODS: We analyzed fixations, smooth pursuits, saccades, and conjugacy measured by a Spearman correlation coefficient and utilized a linear mixed-effects model to estimate the effect of calibration. RESULTS: Healthy participants (n = 18) did not differ in correlations between calibrated and non-calibrated conditions for all tests. The calibration condition did not improve the linear mixed effects model (log-likelihood ratio test p = 0.426) in predicting correlation coefficients. Interestingly, the patient group (n = 17) differed in correlations for the DOT (0.844 [95% CI 0.602, 0.920] vs. 0.98 [95% CI 0.976, 0.985]), H (0.903 [95% CI 0.746, 0.958] vs. 0.979 [95% CI 0.971, 0.986]), and OKN (0.898 [95% CI 0.785, 0.958] vs. 0.993 [95% CI 0.987, 0.996]) tests compared to healthy controls along the x-axis. These differences were not observed along the y-axis. SIGNIFICANCE: This study suggests that automated eye tracking can be deployed without calibration to measure eye movement symmetry. It may be a good discriminator between normal and abnormal eye movement symmetry. Validation of these findings in larger populations is required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Eye MovementsStrokeHumansFixation, OcularSaccadesCalibration

Förderung

  • AHA/ASA

Zitieren

APA

Abul Hassan, M., Aldridge, C. M., Zhuang, Y., Yin, X., McMurry, T., Rohde, G. K., & Southerland, A. M. (2023). Approach to Quantify Eye Movements to Augment Stroke Diagnosis With a Non-Calibrated Eye-Tracker. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2022.3227015

Vancouver

Abul Hassan M, Aldridge CM, Zhuang Y, Yin X, McMurry T, Rohde GK, et al. Approach to Quantify Eye Movements to Augment Stroke Diagnosis With a Non-Calibrated Eye-Tracker. IEEE Transactions on Biomedical Engineering. 2023. doi:10.1109/tbme.2022.3227015

BibTeX
@article{AbulHassan2023,
  author = {Abul Hassan, Mohamed and Aldridge, Chad M and Zhuang, Yan and Yin, Xuwang and McMurry, Timothy and Rohde, Gustavo K and Southerland, Andrew M},
  title = {Approach to Quantify Eye Movements to Augment Stroke Diagnosis With a Non-Calibrated Eye-Tracker},
  journal = {IEEE Transactions on Biomedical Engineering},
  year = {2023},
  doi = {10.1109/tbme.2022.3227015}
}
Kostenlos starten →