A Fast Electrochemical Impedance Spectroscopy With a Square Wave as Excitation Signal for Impedance-Based Biomedical Applications
IEEE Transactions on Biomedical Circuits and Systems · 2025-08 · 19 (4) · 726-742
DOI: 10.1109/tbcas.2025.3579698 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2025-08. Verfasst von Zhongzheng Wang und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Dielectric Spectroscopy, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 70 Literaturangaben. Gefördert von: Science Foundation Ireland (SFI) and the Department of Agriculture, Food and the Marine on behalf of the Government of Ireland, Microelectronic Circuits Centre Ireland (MCCI), through the Enterprise Ireland and IDA Ireland Technology Centers Program.
Abstract (Originalsprache)
This paper introduces a fast, high-accuracy methodology for conducting Electrochemical Impedance Spectroscopy (EIS) based on Fast Fourier Transform (FFT), to meet the requirements of portable, real-time biomedical impedance-based detections with Ultra-Microband (UMB) sensor. Instead of using white noise-like wideband signals as in conventional FFT-based EIS, the proposed method uses a square wave as the excitation signal, which achieves a fast, accurate EIS measurement, but no longer requires complex circuits like high-resolution DACs or frequency mixers for the signal generation. This work starts with the theoretical justification for treating the sensor as a Linear Time-Invariant (LTI), then the practical linear region for operating the sensor as an LTI system is experimentally verified and determined, which enables the capacity of employing the harmonics of a square wave for EIS measurements. A dynamic model of the charge-transfer resistance together with an approximated of the Constant Phase Element (CPE) are implemented with Verilog-A for simulations, and a circuit consisting of a control amplifier and a Trans-Impedance Amplifier (TIA) is designed and fabricated with 65 nm CMOS for validating its on-chip feasibility. This work shortens the EIS measurement time by 91.7% in a frequency sweep range from 0.5 Hz to 500 Hz, with only 2.73% average Mean Absolute Percentage Error (MAPE), compared to a commercial electrochemical instrument AutoLab, with five pre-modified electrodes across four different concentrations of Ferrocene Carboxylic Acid (FcCOOH), demonstrating this method is suitable for portable, real-time label-free EIS biomedical detections and applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Science Foundation Ireland (SFI) and the Department of Agriculture, Food and the Marine on behalf of the Government of Ireland
- Microelectronic Circuits Centre Ireland (MCCI), through the Enterprise Ireland and IDA Ireland Technology Centers Program
Zitieren
APA
Wang, Z., Shao, H., O'Riordan, A., Higes-Marquez, J., O'Connell, I., & O'Hare, D. (2025). A Fast Electrochemical Impedance Spectroscopy With a Square Wave as Excitation Signal for Impedance-Based Biomedical Applications. IEEE Transactions on Biomedical Circuits and Systems, 19(4), 726-742. https://doi.org/10.1109/tbcas.2025.3579698
Vancouver
Wang Z, Shao H, O'Riordan A, Higes-Marquez J, O'Connell I, O'Hare D. A Fast Electrochemical Impedance Spectroscopy With a Square Wave as Excitation Signal for Impedance-Based Biomedical Applications. IEEE Transactions on Biomedical Circuits and Systems. 2025;19(4):726-742. doi:10.1109/tbcas.2025.3579698
BibTeX
@article{Wang2025,
author = {Wang, Zhongzheng and Shao, Han and O'Riordan, Alan and Higes-Marquez, Javier and O'Connell, Ivan and O'Hare, Daniel},
title = {A Fast Electrochemical Impedance Spectroscopy With a Square Wave as Excitation Signal for Impedance-Based Biomedical Applications},
journal = {IEEE Transactions on Biomedical Circuits and Systems},
year = {2025},
volume = {19},
number = {4},
pages = {726--742},
doi = {10.1109/tbcas.2025.3579698}
}