EUVIMEDEUVIMED entdecken
Crossref

System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification

Tzu-Hsuan Chou, Siyuan Yu, Calder Wilson, Jacob Dawes, Jaehyeong Park, Louis Marun, Matthew L Johnston

IEEE Transactions on Biomedical Circuits and Systems · 2025

DOI: 10.1109/tbcas.2025.3576317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2025. Verfasst von Tzu-Hsuan Chou und 6 weiteren Autor:innen. Hauptthemen laut MEDLINE: Flow Cytometry, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Center for Design of Analog-Digital Integrated Circuits, Hewlett-Packard Development Company, Oregon Metals Initiative.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents an impedance measurement system-on-chip (SoC) for flow cytometry (i.e. cell counting) applications. A source-differential, three-electrode sensing scheme is used in a microfluidic flow cell for particle detection. At the front-end, a lock-in amplifier architecture is used, including a high-gain TIA with 60 MHz bandwidth, passive mixers, and low-pass filters. The ac sensor signal is demodulated to extract in-phase (I) and quadrature (Q) baseband components to measure complex impedance. At the back-end, the SoC includes an 8-bit level-crossing ADC (LCADC) for digitizing I/Q signals, followed by real-time digital feature extraction and linear classification for real-time cell size determination. The SoC was fabricated in a 180 nm CMOS process. A measured prototype IC achieves 733 fA/$\sqrt{Hz}$ noise floor and 23 pArms input-referred noise from 1-1 kHz. Combined with a microfluidic flow cell, polymer beads in solution were used as cell surrogates to demonstrate particle counting. Measured results for particle diameters of 10 $\mu$m, 6 $\mu$m, 4.5 $\mu$m and 3 $\mu$m are shown. Following offline training, the SoC demonstrated on-chip classification of 4.5 $\mu$m and 6 $\mu$m beads with a prediction accuracy of 86.16% with pre-recorded data, and 73.6 % while performing real-time inline classification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flow CytometryLab-On-A-Chip DevicesElectric ImpedanceEquipment DesignHumansSignal Processing, Computer-AssistedMicrofluidic Analytical Techniques

Förderung

  • Center for Design of Analog-Digital Integrated Circuits
  • Hewlett-Packard Development Company
  • Oregon Metals Initiative

Zitieren

APA

Chou, T. H., Yu, S., Wilson, C., Dawes, J., Park, J., Marun, L., & Johnston, M. L. (2025). System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2025.3576317

Vancouver

Chou TH, Yu S, Wilson C, Dawes J, Park J, Marun L, et al. System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification. IEEE Transactions on Biomedical Circuits and Systems. 2025. doi:10.1109/tbcas.2025.3576317

BibTeX
@article{Chou2025,
  author = {Chou, Tzu-Hsuan and Yu, Siyuan and Wilson, Calder and Dawes, Jacob and Park, Jaehyeong and Marun, Louis and Johnston, Matthew L},
  title = {System-on-Chip for Flow Cytometry With Impedance Measurement and Integrated Real-Time Size Classification},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2025},
  doi = {10.1109/tbcas.2025.3576317}
}
Kostenlos starten →