EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment

Thorir Mar Ingolfsson, Xiaying Wang, Upasana Chakraborty, Simone Benatti, Adriano Bernini, Pauline Ducouret, Philippe Ryvlin, Sándor Beniczky, Luca Benini, Andrea Cossettini

IEEE Transactions on Biomedical Circuits and Systems · 2024-08 · 18 (4) · 720-733

DOI: 10.1109/tbcas.2024.3395534 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024-08. Verfasst von Thorir Mar Ingolfsson und 9 weiteren Autor:innen. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation, ETH-Domain Joint Initiative program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introducesBrainFuseNet, a novel lightweight seizure detection network based on the sensor fusion of electroencephalography (EEG) with photoplethysmography (PPG) and accelerometer (ACC) signals, tailored for low-channel count wearable systems.BrainFuseNetutilizes the Sensitivity-Specificity Weighted Cross-Entropy (SSWCE), an innovative loss function incorporating sensitivity and specificity, to address the challenge of heavily unbalanced datasets. TheBrainFuseNet-SSWCE approach successfully detects$93.5\%$seizure events on the CHB-MIT dataset ($76.34\%$sample-based sensitivity), for EEG-based classification with only four channels. On the PEDESITE dataset, we demonstrate a sample-based sensitivity and false positive rate of$60.66\%$and$1.18$FP/h, respectively, when considering EEG data alone. Additionally, we demonstrate that integrating PPG signals increases the sensitivity to$61.22\%$(successfully detecting$92\%$seizure events) while decreasing the number of false positives to$1.0$FP/h. Finally, when ACC data are also considered, the sensitivity increases to$64.28\%$(successfully detecting$95\%$seizure events) and the number of false positives drops to only$0.21$FP/h for sample-based estimations, with less than one false alarm per day when considering event-based estimations.BrainFuseNetis resource-friendly and well-suited for implementation on low-power embedded platforms, and we evaluate its performance on GAP9, a state-of-the-art parallel ultra-low power (PULP) microcontroller for tiny Machine Learning applications on wearables. The implementation on GAP9 achieves an energy efficiency of$21.43$GMAC/s/W, with an energy consumption per inference of only$0.11$mJ at high performance ($412.54$MMAC/s). TheBrainFuseNet-SSWCE method demonstrates effective and accurate seizure detection on heavily imbalanced datasets while achieving state-of-the-art performance in the false positive rate and being well-suited for deployment on energy-constrained edge devices.

Förderung

  • Swiss National Science Foundation
  • ETH-Domain Joint Initiative program

Zitieren

APA

Ingolfsson, T. M., Wang, X., Chakraborty, U., Benatti, S., Bernini, A., Ducouret, P., Ryvlin, P., Beniczky, S., Benini, L., & Cossettini, A. (2024). BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment. IEEE Transactions on Biomedical Circuits and Systems, 18(4), 720-733. https://doi.org/10.1109/tbcas.2024.3395534

Vancouver

Ingolfsson TM, Wang X, Chakraborty U, Benatti S, Bernini A, Ducouret P, et al. BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment. IEEE Transactions on Biomedical Circuits and Systems. 2024;18(4):720-733. doi:10.1109/tbcas.2024.3395534

BibTeX
@article{Ingolfsson2024,
  author = {Ingolfsson, Thorir Mar and Wang, Xiaying and Chakraborty, Upasana and Benatti, Simone and Bernini, Adriano and Ducouret, Pauline and Ryvlin, Philippe and Beniczky, Sándor and Benini, Luca and Cossettini, Andrea},
  title = {BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2024},
  volume = {18},
  number = {4},
  pages = {720--733},
  doi = {10.1109/tbcas.2024.3395534}
}
Kostenlos starten →