BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment
IEEE Transactions on Biomedical Circuits and Systems · 2024-08 · 18 (4) · 720-733
DOI: 10.1109/tbcas.2024.3395534 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024-08. Verfasst von Thorir Mar Ingolfsson und 9 weiteren Autor:innen. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation, ETH-Domain Joint Initiative program.
Abstract (Originalsprache)
This paper introducesBrainFuseNet, a novel lightweight seizure detection network based on the sensor fusion of electroencephalography (EEG) with photoplethysmography (PPG) and accelerometer (ACC) signals, tailored for low-channel count wearable systems.BrainFuseNetutilizes the Sensitivity-Specificity Weighted Cross-Entropy (SSWCE), an innovative loss function incorporating sensitivity and specificity, to address the challenge of heavily unbalanced datasets. TheBrainFuseNet-SSWCE approach successfully detects$93.5\%$seizure events on the CHB-MIT dataset ($76.34\%$sample-based sensitivity), for EEG-based classification with only four channels. On the PEDESITE dataset, we demonstrate a sample-based sensitivity and false positive rate of$60.66\%$and$1.18$FP/h, respectively, when considering EEG data alone. Additionally, we demonstrate that integrating PPG signals increases the sensitivity to$61.22\%$(successfully detecting$92\%$seizure events) while decreasing the number of false positives to$1.0$FP/h. Finally, when ACC data are also considered, the sensitivity increases to$64.28\%$(successfully detecting$95\%$seizure events) and the number of false positives drops to only$0.21$FP/h for sample-based estimations, with less than one false alarm per day when considering event-based estimations.BrainFuseNetis resource-friendly and well-suited for implementation on low-power embedded platforms, and we evaluate its performance on GAP9, a state-of-the-art parallel ultra-low power (PULP) microcontroller for tiny Machine Learning applications on wearables. The implementation on GAP9 achieves an energy efficiency of$21.43$GMAC/s/W, with an energy consumption per inference of only$0.11$mJ at high performance ($412.54$MMAC/s). TheBrainFuseNet-SSWCE method demonstrates effective and accurate seizure detection on heavily imbalanced datasets while achieving state-of-the-art performance in the false positive rate and being well-suited for deployment on energy-constrained edge devices.
Förderung
- Swiss National Science Foundation
- ETH-Domain Joint Initiative program
Zitieren
APA
Ingolfsson, T. M., Wang, X., Chakraborty, U., Benatti, S., Bernini, A., Ducouret, P., Ryvlin, P., Beniczky, S., Benini, L., & Cossettini, A. (2024). BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment. IEEE Transactions on Biomedical Circuits and Systems, 18(4), 720-733. https://doi.org/10.1109/tbcas.2024.3395534
Vancouver
Ingolfsson TM, Wang X, Chakraborty U, Benatti S, Bernini A, Ducouret P, et al. BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment. IEEE Transactions on Biomedical Circuits and Systems. 2024;18(4):720-733. doi:10.1109/tbcas.2024.3395534
BibTeX
@article{Ingolfsson2024,
author = {Ingolfsson, Thorir Mar and Wang, Xiaying and Chakraborty, Upasana and Benatti, Simone and Bernini, Adriano and Ducouret, Pauline and Ryvlin, Philippe and Beniczky, Sándor and Benini, Luca and Cossettini, Andrea},
title = {BrainFuseNet: Enhancing Wearable Seizure Detection Through EEG-PPG-Accelerometer Sensor Fusion and Efficient Edge Deployment},
journal = {IEEE Transactions on Biomedical Circuits and Systems},
year = {2024},
volume = {18},
number = {4},
pages = {720--733},
doi = {10.1109/tbcas.2024.3395534}
}
EUVIMED