EUVIMEDEUVIMED entdecken
Crossref

A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing

Mark Daniel Alea, Ali Safa, Flavio Giacomozzi, Andrea Adami, Inci Ruya Temel, Maria Atalaia Rosa, Leandro Lorenzelli, Georges Gielen

IEEE Transactions on Biomedical Circuits and Systems · 2024

DOI: 10.1109/tbcas.2024.3387545 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024. Verfasst von Mark Daniel Alea und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Fingers, Touch, Biomimetics. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents an electronic skin (e-skin) taxel array readout chip in 0.18m CMOS technology, achieving the highest reported spatial resolution of 200m, comparable to human fingertips. A key innovation is the integration on chip of a 1216 polyvinylidene fluoride (PVDF)-based piezoelectric sensor array with per-taxel signal conditioning frontend and spiking readout combined with local embedded neuromorphic first-order processing through Complex Receptive Fields (CRFs). Experimental results show that Spiking Neural Network (SNN)-based classification of the chip's spatiotemporal spiking output for input tactile stimuli such as texture and flutter frequency achieves excellent accuracies up to 97.1 and 99.2, respectively. SNN-based classification of the indentation period applied to the on-chip PVDF sensors achieved 95.5 classification accuracy, despite using only a small 256-neuron SNN classifier, a low equivalent spike encoding resolution of 3-5 bits, and a sub-Nyquist 2.2kevent/s population spiking rate, a state-of-the-art power consumption of 12.33nW per-taxel, and 75W-5mW for the entire chip is obtained. Finally, a comparison of the texture classification accuracies between two on-chip spike encoder outputs shows that the proposed neuromorphic level-crossing sampling (N-LCS) architecture with a decaying threshold outperforms the conventional bipolar level-crossing sampling (LCS) architecture with fixed threshold.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesFingersTouchBiomimeticsNeural Networks, ComputerRoboticsSemiconductorsHumansFluorocarbon PolymersPolyvinyls

Substanzen

polyvinylidene fluorideFluorocarbon PolymersPolyvinyls

Zitieren

APA

Alea, M. D., Safa, A., Giacomozzi, F., Adami, A., Temel, I. R., Rosa, M. A., Lorenzelli, L., & Gielen, G. (2024). A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2024.3387545

Vancouver

Alea MD, Safa A, Giacomozzi F, Adami A, Temel IR, Rosa MA, et al. A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing. IEEE Transactions on Biomedical Circuits and Systems. 2024. doi:10.1109/tbcas.2024.3387545

BibTeX
@article{Alea2024,
  author = {Alea, Mark Daniel and Safa, Ali and Giacomozzi, Flavio and Adami, Andrea and Temel, Inci Ruya and Rosa, Maria Atalaia and Lorenzelli, Leandro and Gielen, Georges},
  title = {A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2024},
  doi = {10.1109/tbcas.2024.3387545}
}
Kostenlos starten →