A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing
IEEE Transactions on Biomedical Circuits and Systems · 2024
DOI: 10.1109/tbcas.2024.3387545 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024. Verfasst von Mark Daniel Alea und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Fingers, Touch, Biomimetics. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
This paper presents an electronic skin (e-skin) taxel array readout chip in 0.18m CMOS technology, achieving the highest reported spatial resolution of 200m, comparable to human fingertips. A key innovation is the integration on chip of a 1216 polyvinylidene fluoride (PVDF)-based piezoelectric sensor array with per-taxel signal conditioning frontend and spiking readout combined with local embedded neuromorphic first-order processing through Complex Receptive Fields (CRFs). Experimental results show that Spiking Neural Network (SNN)-based classification of the chip's spatiotemporal spiking output for input tactile stimuli such as texture and flutter frequency achieves excellent accuracies up to 97.1 and 99.2, respectively. SNN-based classification of the indentation period applied to the on-chip PVDF sensors achieved 95.5 classification accuracy, despite using only a small 256-neuron SNN classifier, a low equivalent spike encoding resolution of 3-5 bits, and a sub-Nyquist 2.2kevent/s population spiking rate, a state-of-the-art power consumption of 12.33nW per-taxel, and 75W-5mW for the entire chip is obtained. Finally, a comparison of the texture classification accuracies between two on-chip spike encoder outputs shows that the proposed neuromorphic level-crossing sampling (N-LCS) architecture with a decaying threshold outperforms the conventional bipolar level-crossing sampling (LCS) architecture with fixed threshold.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Zitieren
APA
Alea, M. D., Safa, A., Giacomozzi, F., Adami, A., Temel, I. R., Rosa, M. A., Lorenzelli, L., & Gielen, G. (2024). A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2024.3387545
Vancouver
Alea MD, Safa A, Giacomozzi F, Adami A, Temel IR, Rosa MA, et al. A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing. IEEE Transactions on Biomedical Circuits and Systems. 2024. doi:10.1109/tbcas.2024.3387545
BibTeX
@article{Alea2024,
author = {Alea, Mark Daniel and Safa, Ali and Giacomozzi, Flavio and Adami, Andrea and Temel, Inci Ruya and Rosa, Maria Atalaia and Lorenzelli, Leandro and Gielen, Georges},
title = {A Fingertip-Mimicking 12$\times$16 200 $\mu$m-Resolution e -Skin Taxel Readout Chip With Per-Taxel Spiking Readout and Embedded Receptive Field Processing},
journal = {IEEE Transactions on Biomedical Circuits and Systems},
year = {2024},
doi = {10.1109/tbcas.2024.3387545}
}
EUVIMED