Toward a Wireless Image Sensor for Real-Time Fluorescence Microscopy in Cancer Therapy
IEEE Transactions on Biomedical Circuits and Systems · 2024-10 · 18 (5) · 1050-1064
DOI: 10.1109/tbcas.2024.3374886 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024-10. Verfasst von Rozhan Rabbani und 8 weiteren Autor:innen. Hauptthemen laut MEDLINE: Microscopy, Fluorescence, Wireless Technology. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: NIDCR NIH HHS, Office of the Director and the National Institute of Dental and Craniofacial Research of the National Institutes of Health, John V. Carbone Jr. Pancreatic Cancer Research Memorial Fund.
Abstract (Originalsprache)
We present a mm-sized, ultrasonically powered lensless CMOS image sensor as a progress towards wireless fluorescence microscopy. Access to biological information within the tissue has the potential to provide insights guiding diagnosis and treatment across numerous medical conditions including cancer therapy. This information, in conjunction with current clinical imaging techniques that have limitations in obtaining images continuously and lack wireless compatibility, can improve continual detection of multicell clusters deep within tissue. The proposed platform incorporates a 2.4 × 4.7 mm2 integrated circuit (IC) fabricated in TSMC 0.18 µm, a micro laser diode (µLD), a single piezoceramic and off-chip storage capacitors. The IC consists of a 36 × 40 array of capacitive trans-impedance amplifier-based pixels, wireless power management and communication via ultrasound and a laser driver all controlled by a Finite State Machine. The piezoceramic harvests energy from the acoustic waves at a depth of 2 cm to power up the IC and transfer 11.5 kbits/frame via backscattering. During Charge-Up, the off-chip capacitor stores charge to later supply a high-power 78 mW µLD during Imaging. Proof of concept of the imaging front end is shown by imaging distributions of CD8 T-cells, an indicator of the immune response to cancer, ex vivo, in the lymph nodes of a functional immune system (BL6 mice) against colorectal cancer consistent with the results of a fluorescence microscope. The overall system performance is verified by detecting 140 µm features on a USAF resolution target with 32 ms exposure time and 389 ms ultrasound backscattering.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- NIDCR NIH HHS
- Office of the Director and the National Institute of Dental and Craniofacial Research of the National Institutes of Health
- John V. Carbone Jr. Pancreatic Cancer Research Memorial Fund
Zitieren
APA
Rabbani, R., Najafiaghdam, H., Roschelle, M., Papageorgiou, E. P., Zhao, B. R., Ghanbari, M. M., Muller, R., Stojanovic, V., & Anwar, M. (2024). Toward a Wireless Image Sensor for Real-Time Fluorescence Microscopy in Cancer Therapy. IEEE Transactions on Biomedical Circuits and Systems, 18(5), 1050-1064. https://doi.org/10.1109/tbcas.2024.3374886
Vancouver
Rabbani R, Najafiaghdam H, Roschelle M, Papageorgiou EP, Zhao BR, Ghanbari MM, et al. Toward a Wireless Image Sensor for Real-Time Fluorescence Microscopy in Cancer Therapy. IEEE Transactions on Biomedical Circuits and Systems. 2024;18(5):1050-1064. doi:10.1109/tbcas.2024.3374886
BibTeX
@article{Rabbani2024,
author = {Rabbani, Rozhan and Najafiaghdam, Hossein and Roschelle, Micah and Papageorgiou, Efthymios Philip and Zhao, Biqi Rebekah and Ghanbari, Mohammad Meraj and Muller, Rikky and Stojanovic, Vladimir and Anwar, Mekhail},
title = {Toward a Wireless Image Sensor for Real-Time Fluorescence Microscopy in Cancer Therapy},
journal = {IEEE Transactions on Biomedical Circuits and Systems},
year = {2024},
volume = {18},
number = {5},
pages = {1050--1064},
doi = {10.1109/tbcas.2024.3374886}
}