EUVIMEDEUVIMED entdecken
Open Access

A Spatially Diverse 2TX-3RX Galvanic-Coupled Transdural Telemetry for Tether-Less Distributed Brain–Computer Interfaces

Chengyao Shi, Yuming He, Marios Gourdouparis, Guido Dolmans, Yao-Hong Liu

IEEE Transactions on Biomedical Circuits and Systems · 2024

DOI: 10.1109/tbcas.2024.3373172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2024. Verfasst von Chengyao Shi und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Brain-Computer Interfaces, Telemetry. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: European Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A near-field galvanic coupled transdural telemetry ASICs for intracortical brain-computer interfaces is presented. The proposed design features a two channels transmitter and three channels receiver (2TX-3RX) topology, which introduces spatial diversity to effectively mitigate misalignments (both lateral and rotational) between the brain and the skull and recovers the path loss by 13 dB when the RX is in the worst-case blind spot. This spatial diversity also allows the presented telemetry to support the spatial division multiplexing required for a high-capacity multi-implant distributed network. It achieves a signal-to-interference ratio of 12 dB, even with the adjacent interference node placed only 8 mm away from the desired link. While consuming only 0.33 mW for each channel, the presented RX achieves a wide bandwidth of 360 MHz and a low input referred noise of 13.21 nV/√Hz. The presented telemetry achieves a 270 Mbps data rate with a BER < 10-6 and an energy efficiency of 3.4 pJ/b and 3.7 pJ/b, respectively. The core footprint of the TX and RX modules is only 100 and 52 mm2, respectively, minimizing the invasiveness of the surgery. The proposed transdural telemetry system has been characterized ex-vivo with a 7-mm thick porcine tissue.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain-Computer InterfacesTelemetrySignal Processing, Computer-AssistedHumansEquipment DesignWireless TechnologyAnimalsBrain

Förderung

  • European Research Council

Zitieren

APA

Shi, C., He, Y., Gourdouparis, M., Dolmans, G., & Liu, Y. H. (2024). A Spatially Diverse 2TX-3RX Galvanic-Coupled Transdural Telemetry for Tether-Less Distributed Brain–Computer Interfaces. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2024.3373172

Vancouver

Shi C, He Y, Gourdouparis M, Dolmans G, Liu YH. A Spatially Diverse 2TX-3RX Galvanic-Coupled Transdural Telemetry for Tether-Less Distributed Brain–Computer Interfaces. IEEE Transactions on Biomedical Circuits and Systems. 2024. doi:10.1109/tbcas.2024.3373172

BibTeX
@article{Shi2024,
  author = {Shi, Chengyao and He, Yuming and Gourdouparis, Marios and Dolmans, Guido and Liu, Yao-Hong},
  title = {A Spatially Diverse 2TX-3RX Galvanic-Coupled Transdural Telemetry for Tether-Less Distributed Brain–Computer Interfaces},
  journal = {IEEE Transactions on Biomedical Circuits and Systems},
  year = {2024},
  doi = {10.1109/tbcas.2024.3373172}
}
Kostenlos starten →