Bio-Hash Secured Hardware e-Health Record System
IEEE Transactions on Biomedical Circuits and Systems · 2023
DOI: 10.1109/tbcas.2023.3263177 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Circuits and Systems, 2023. Verfasst von M M Sravani und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Data Compression, Telemedicine. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: VIT Chennai.
Abstract (Originalsprache)
Dual securing strategy for all-hardware e-Health Record System is designed and developed for improved security and reduced Hardware Execution Time (HET). A compact novel Hashed Minutiae Random Fusion (HMRF) logic enables to achieve high irreversibility and increased non-reconstruction capability of the bio-template based Bio-Hash key. AES encryption of the patient's health data during Write mode and decryption during View mode are seamlessly performed through the lively generated key, yielding low HET through optimized slack. On the other hand, biometric controlled key retrieval during Read only mode for a single user access is performed on the pre-scrambled Bio-Hash key, to enable bypassed decryption (direct) of the Patient's health data for self-review. The proposed pseudo cascaded SHA-3 (Secured Hash Algorithm) architecture being the first stage in HMRF, hashes the biometric minutiae of both Patient (P) and Medical Practitioner (MP) with low Latency. Thus, facilitating in further lowering of the HET by reducing the clock count by one. The subsequent Random Compression Logic (RCL) skims the hashed value from 512 to 128 bits along with the help of priority compression logic (PCL) to achieve reduced bits handling thereby lowering the Power budget. Four fusion modes are leveraged to achieve better randomization and non-recoverability. Implementation of this HMRF logic on Virtex-7 (V7) FPGA device has yielded low Area of 4191 slices. Lesser Area of 11.6% is observed for this HMRF module compared to the reported design, excluding level shifter and PCL. Further, low HETs of 8.2/8.3/8.0 ns during Write/View/Read only modes respectively are being noticed. The dynamic Power dissipated for the three modes of operations are found to be 1.418/1.420/0.676 watts respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- VIT Chennai
Zitieren
APA
Sravani, M. M., & Durai, S. A. (2023). Bio-Hash Secured Hardware e-Health Record System. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2023.3263177
Vancouver
Sravani MM, Durai SA. Bio-Hash Secured Hardware e-Health Record System. IEEE Transactions on Biomedical Circuits and Systems. 2023. doi:10.1109/tbcas.2023.3263177
BibTeX
@article{Sravani2023,
author = {Sravani, M M and Durai, S Ananiah},
title = {Bio-Hash Secured Hardware e-Health Record System},
journal = {IEEE Transactions on Biomedical Circuits and Systems},
year = {2023},
doi = {10.1109/tbcas.2023.3263177}
}
EUVIMED