EUVIMEDEUVIMED entdecken
Crossref

MonoEndoCal: Autonomous Calibration for Tendon-Driven Endoscopic Robots Using Monocular Vision

Dong-Geol Lee, Dong-Ho Lee, Dong-Soo Kwon, Jee-Hwan Ryu, Hansoul Kim

IEEE Transactions on Automation Science and Engineering · 2026 · 23 · 12579-12591

DOI: 10.1109/tase.2026.3711078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Automation Science and Engineering, 2026. Verfasst von Dong-Geol Lee und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Gefördert von: 2024 Research Fund of Myongji University and in part by the National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT (MSIT),….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible endoscopic surgical robots provide enhanced access and maneuverability in complex anatomical environments, addressing limitations encountered by conventional rigid robotic systems. However, achieving precise control of these robots remains challenging due to inherent nonlinear hysteresis originating from friction and tendon slack in tendon-driven mechanisms, significantly impacting surgical accuracy and increasing the cognitive workload on surgeons. To overcome these challenges, this study introduces MonoEndoCal, a deep learning-based autonomous calibration framework designed to estimate bending angles and compensate for nonlinear hysteresis using only monocular endoscopic images, without the need for additional sensors or markers. Leveraging advanced vision models—Depth Anything V2 for dense depth estimation and Segment Anything Model 2 for zero-shot segmentation—MonoEndoCal accurately estimates robot bending angles in real-time. These angle estimations, along with corresponding actuation commands, are employed to derive a precise hysteresis model using differential equations capturing the robot’s nonlinear dynamics. By integrating this hysteresis model with robot kinematics, MonoEndoCal implements an effective feedforward control strategy that enables precise hysteresis compensation and enhanced control accuracy. Experimental validations further demonstrate its robustness across varying robot geometries, input characteristics (both periodic and aperiodic), and blood contamination, highlighting its strong potential for improving control precision. Note to Practitioners—Flexible endoscopic surgical robots are increasingly used to enhance precision and reduce patient trauma in minimally invasive procedures. However, accurate control remains challenging due to nonlinear hysteresis in tendon-driven mechanisms, which can significantly affect surgical performance. This work presents MonoEndoCal, a deep learning-based autonomous calibration framework that uses only monocular endoscopic images—without external sensors or markers to estimate bending angles and compensate for hysteresis in real time. From a practical perspective, the proposed method can be integrated into existing endoscopic robotic platforms with minimal hardware modification, making it well-suited for clinical environments with strict space constraints. Practitioners adopting this framework should ensure that real-time computational resources are available and validate the hysteresis model with system-specific calibration data to achieve optimal performance. This approach offers a cost-effective, sensorless calibration solution that can improve control fidelity and reduce surgeon workload in tendon-driven surgical robots.

Förderung

  • 2024 Research Fund of Myongji University and in part by the National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT (MSIT),…

Zitieren

APA

Lee, D., Lee, D., Kwon, D., Ryu, J., & Kim, H. (2026). MonoEndoCal: Autonomous Calibration for Tendon-Driven Endoscopic Robots Using Monocular Vision. IEEE Transactions on Automation Science and Engineering, 23, 12579-12591. https://doi.org/10.1109/tase.2026.3711078

Vancouver

Lee D, Lee D, Kwon D, Ryu J, Kim H. MonoEndoCal: Autonomous Calibration for Tendon-Driven Endoscopic Robots Using Monocular Vision. IEEE Transactions on Automation Science and Engineering. 2026;23:12579-12591. doi:10.1109/tase.2026.3711078

BibTeX
@article{Lee2026,
  author = {Lee, Dong-Geol and Lee, Dong-Ho and Kwon, Dong-Soo and Ryu, Jee-Hwan and Kim, Hansoul},
  title = {MonoEndoCal: Autonomous Calibration for Tendon-Driven Endoscopic Robots Using Monocular Vision},
  journal = {IEEE Transactions on Automation Science and Engineering},
  year = {2026},
  volume = {23},
  pages = {12579--12591},
  doi = {10.1109/tase.2026.3711078}
}
Kostenlos starten →