Fachartikel in der Zeitschrift IEEE Transactions on Automation Science and Engineering, 2026. Verfasst von Haofeng Liu und 5 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Gefördert von: National Key R&D Program of China “Remote monitoring and fault diagnosis technology for offshore wind power grid connected systems”.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time parameter estimation captures the time-varying behavior of line parameters, preventing attackers from maintaining an accurate system model. As attackers rely on outdated parameter information, the measurement effects of their injections no longer align with the attacker’s intended outcomes, rendering perfectly stealthy False Data Injection Attacks (FDIAs) ineffective. This paper introduces Confusion False Data Injection Attacks (CFDIAs), which exploit the mismatch between an attacker’s outdated model and the system’s time-varying reality. CFDIAs reshape the resulting measurement discrepancies so they fall within the statistical behavior of normal noise, enabling approximate stealthiness under residual-based detection. A bi-level optimization framework is established to quantify the economic impacts of CFDIAs. The upper level designs approximately stealthy attacks, while the lower level performs optimal power flow. A Conservative Chance-Constraint Linearization (CCCL) technique is incorporated to provide a geometric and tractable approximation of nonlinear chance constraints. The results show that real-time parameter updates can create a false sense of protection, as some lines that appear secure remain covertly exploitable by CFDIAs. Experiments further demonstrate that such attacks can raise dispatch costs by 33.16% in the IEEE 30-bus system and 27.21% in the 89-bus system. Note to Practitioners—Real-time parameter estimation enhances system defenses by continuously updating line parameters and the associated measurement model. Because attackers cannot obtain these real-time updates, they must rely on outdated model information. This information gap causes a mismatch between the attack they design and the actual measurement changes, making perfectly stealthy False Data Injection Attacks (FDIAs) no longer feasible. However, attackers can still launch Confusion False Data Injection Attacks (CFDIAs). They do so by disguising the discrepancies caused by this mismatch as normal measurement noise, enabling approximate stealthiness. Through a bi-level optimization framework, we quantify the resulting operational impacts and observe that certain transmission lines, although appearing secured under traditional FDIAs, remain economically exploitable under noise-camouflaged attacks—leading to dispatch-cost increases of 33.16% in the IEEE 30-bus system and 27.21% in the 89-bus system. For practitioners, this highlights a critical blind spot: residual-based detectors may still interpret malicious deviations as ordinary noise when these deviations are statistically aligned with measurement uncertainties, indicating that real-time parameter updates alone are insufficient to ensure security.

Förderung

  • National Key R&D Program of China “Remote monitoring and fault diagnosis technology for offshore wind power grid connected systems”

Zitieren

APA

Liu, H., Qin, L., Ran, X., Wang, J., Zhang, C., & Liu, K. (2026). Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems. IEEE Transactions on Automation Science and Engineering, 23, 10883-10898. https://doi.org/10.1109/tase.2026.3700820

Vancouver

Liu H, Qin L, Ran X, Wang J, Zhang C, Liu K. Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems. IEEE Transactions on Automation Science and Engineering. 2026;23:10883-10898. doi:10.1109/tase.2026.3700820

BibTeX
@article{Liu2026,
  author = {Liu, Haofeng and Qin, Liang and Ran, Xiaohong and Wang, Jing and Zhang, Changwen and Liu, Kaipei},
  title = {Confusion False Data Injection Attacks and Novel Load Redistribution Schedule Under Line Parameters Fluctuations in Power Systems},
  journal = {IEEE Transactions on Automation Science and Engineering},
  year = {2026},
  volume = {23},
  pages = {10883--10898},
  doi = {10.1109/tase.2026.3700820}
}
Kostenlos starten →