EUVIMEDEUVIMED entdecken
Crossref

LANTERN: Characterization Technology for Low Threshold Cryogenic Detectors

G. Del Castello

IEEE Transactions on Applied Superconductivity · 2026-09 · 36 (6) · 2503406-2503406

DOI: 10.1109/tasc.2026.3711768 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-09. Verfasst von G. Del Castello. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 7 Literaturangaben. Gefördert von: Sapienza University, European Commission.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered low-energy rare event searches. Characterizing these detectors within the region of interest (ROI), typically from O(10~eV) to O(1~keV), is a challenging task. Conventional radioactive sources produce signals above this range which can be affected by saturation effects. Moreover, these detectors are usually deployed in low background environments, making the use of a radioactive source during physics runs unfeasible. We introduce LANTERN, an optical calibration system for highly segmented cryogenic calorimeters. LANTERN utilizes the photostatistics from the absorption of UV-Vis photons emitted by LEDs to characterize the detector response. The system employs a 64 LED matrix, with switching times faster than the response of cryogenic detectors, and induces particle-like signals on the detector in a wide energy range, from a few eV to hundreds of keV, allowing for a complete study of the response of the detector within the ROI. In this work, the validation of the final electronics designed for the project is shown. The first test, carried out by calibrating one of the BULLKID cryogenic detectors and cross-checking the energy-reconstruction error using the environmental background, yieleded a calibration accuracy of $\approx 2\%$. The second validation, carried out by cross-calibrating a CALDER detector with a commercial LED driver, gave compatible results between the two setups. LANTERN is now ready for its full deployment in BULLKID, while its usage in the CRAB and NUCLEUS experiments is also currently being investigated.

Förderung

  • Sapienza University
  • European Commission

Zitieren

APA

Castello, G. D. (2026). LANTERN: Characterization Technology for Low Threshold Cryogenic Detectors. IEEE Transactions on Applied Superconductivity, 36(6), 2503406-2503406. https://doi.org/10.1109/tasc.2026.3711768

Vancouver

Castello GD. LANTERN: Characterization Technology for Low Threshold Cryogenic Detectors. IEEE Transactions on Applied Superconductivity. 2026;36(6):2503406-2503406. doi:10.1109/tasc.2026.3711768

BibTeX
@article{Castello2026,
  author = {Castello, G. Del},
  title = {LANTERN: Characterization Technology for Low Threshold Cryogenic Detectors},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {2503406--2503406},
  doi = {10.1109/tasc.2026.3711768}
}