Development and Characterization of KID-Based SPIAKID Instrument

Zhaohang Peng, Faouzi Boussaha, Piercarlo Bonifacio, Jie Hu, Paul Nicaise, Christine Chaumont, Florent Reix, Josiane Firminy, Elisabetta Caffau, Cyril Pannetier, Jean-Philippe Amans, Moustapha Dekkali und 4 weitere

IEEE Transactions on Applied Superconductivity · 2026-09 · 36 (6) · 2402406-2402406

DOI: 10.1109/tasc.2026.3696967 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-09. Verfasst von Zhaohang Peng und 15 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Gefördert von: European Research Council, UnivEarhS Labex program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The SpectroPhotometric Imaging in Astronomy with Kinetic Inductance Detectors (SPIAKID) instrument is designed and currently being developed to explore ultra-faint dwarf galaxies in the optical and near-infrared bands. We envisage to install SPIAKID at the New Technology Telescope in Chile as a guest instrument and targets a field of view of 2’ × 2’, which can be achieved using four 20 000-pixel arrays at the focal plane. Each array is divided into 10 subarrays, with 2000 pixels per feedline. The superconducting kinetic inductance detector (KID) comprises a TiN/Ti/TiN trilayer meander and an Nb interdigitated capacitor. In a newly developed antivibration dilution cryostat, 10 readout lines were constructed utilizing 10 low-noise amplifiers. The performance of the device is characterized using a vector network analyzer and a homodyne scheme at various temperatures between 20 and 495 mK, producing preliminary results of pulse response and energy resolution (energy resolving power) under illumination delivered through an optical fiber at 405 nm. The measured resonant frequencies of the KIDs range from 3.8 to 8.5 GHz. The energy resolution of the resonator initially improves with increasing temperature but subsequently degrades. So far, the best measured energy resolution is 2.5 at 275 mK and 405 nm.

Förderung

  • European Research Council
  • UnivEarhS Labex program

Zitieren

APA

Peng, Z., Boussaha, F., Bonifacio, P., Hu, J., Nicaise, P., Chaumont, C., Reix, F., Firminy, J., Caffau, E., Pannetier, C., Amans, J., Dekkali, M., Vacelet, T., Marret, A., Horville, D., & Piat, M. (2026). Development and Characterization of KID-Based SPIAKID Instrument. IEEE Transactions on Applied Superconductivity, 36(6), 2402406-2402406. https://doi.org/10.1109/tasc.2026.3696967

Vancouver

Peng Z, Boussaha F, Bonifacio P, Hu J, Nicaise P, Chaumont C, et al. Development and Characterization of KID-Based SPIAKID Instrument. IEEE Transactions on Applied Superconductivity. 2026;36(6):2402406-2402406. doi:10.1109/tasc.2026.3696967

BibTeX
@article{Peng2026,
  author = {Peng, Zhaohang and Boussaha, Faouzi and Bonifacio, Piercarlo and Hu, Jie and Nicaise, Paul and Chaumont, Christine and Reix, Florent and Firminy, Josiane and Caffau, Elisabetta and Pannetier, Cyril and Amans, Jean-Philippe and Dekkali, Moustapha and Vacelet, Thibaut and Marret, Alexine and Horville, David and Piat, Michel},
  title = {Development and Characterization of KID-Based SPIAKID Instrument},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {2402406--2402406},
  doi = {10.1109/tasc.2026.3696967}
}
Kostenlos starten →