EUVIMEDEUVIMED entdecken
Crossref

Development of a High-Sensitivity, 80-mm Long-Baseline, Monolithically Integrated SQUID First-Order Gradiometer

Shumin Yu, Guofeng Zhang, Jun Wu, Jiawei Luo, Yongliang Wang, Longqing Qiu, Liangliang Rong

IEEE Transactions on Applied Superconductivity · 2026-10 · 36 (7) · 1-7

DOI: 10.1109/tasc.2026.3685353 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-10. Verfasst von Shumin Yu und 6 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Gefördert von: Postdoctoral Fellowship Program of CPSF.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a high-sensitivity, monolithically integrated SQUID first-order gradiometer with an 80-mm long baseline. The device exhibits a magnetic gradient noise as low as 10 fT/(m·√Hz), representing an approximately 20% improvement over the current state-of-the-art. This achievement is attributed to a combination of innovations in both design and fabrication. In the design phase, theoretical analysis and numerical simulations were employed to optimize the SQUID and pickup coil parameters, achieving an optimal balance between coupling efficiency and parasitic effects. This yielded superior intrinsic performance, including a voltage swing of 217 μV, a voltage-to-flux transfer coefficient of 1450 μV/Φ0, and a magnetic gradient-to-flux conversion coefficient of 9.66 nT/m/Φ0. In fabrication, an optimized hybrid lithography process addressed the cross-scale challenges from 80 mm to submicron levels. Furthermore, the introduction of organic cleaning and the optimization of metal wiring thickness effectively resolved step coverage issues, significantly improving device yield. These outstanding intrinsic properties significantly reduce noise contributions from the readout circuitry, thereby enabling a substantial improvement in overall system performance. This work demonstrates the fabrication feasibility and exceptional performance of long-baseline integrated SQUID gradiometers, laying a technological foundation for next-generation ultra-high-sensitivity magnetic sensing systems.

Förderung

  • Postdoctoral Fellowship Program of CPSF

Zitieren

APA

Yu, S., Zhang, G., Wu, J., Luo, J., Wang, Y., Qiu, L., & Rong, L. (2026). Development of a High-Sensitivity, 80-mm Long-Baseline, Monolithically Integrated SQUID First-Order Gradiometer. IEEE Transactions on Applied Superconductivity, 36(7), 1-7. https://doi.org/10.1109/tasc.2026.3685353

Vancouver

Yu S, Zhang G, Wu J, Luo J, Wang Y, Qiu L, et al. Development of a High-Sensitivity, 80-mm Long-Baseline, Monolithically Integrated SQUID First-Order Gradiometer. IEEE Transactions on Applied Superconductivity. 2026;36(7):1-7. doi:10.1109/tasc.2026.3685353

BibTeX
@article{Yu2026,
  author = {Yu, Shumin and Zhang, Guofeng and Wu, Jun and Luo, Jiawei and Wang, Yongliang and Qiu, Longqing and Rong, Liangliang},
  title = {Development of a High-Sensitivity, 80-mm Long-Baseline, Monolithically Integrated SQUID First-Order Gradiometer},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {7},
  pages = {1--7},
  doi = {10.1109/tasc.2026.3685353}
}
Kostenlos starten →