EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of 90 GHz Polarization-Sensitive LEKIDs for CMB Experiments

I. Di Nitto, F. Cacciotti, P. de Bernardis, A. Coppolecchia, L. Lamagna, S. Masi, A. Paiella, G. Pettinari, A. Volpe

IEEE Transactions on Applied Superconductivity · 2026-09 · 36 (6) · 1-8

DOI: 10.1109/tasc.2026.3682965 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-09. Verfasst von I. Di Nitto und 8 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Kinetic inductance detectors (KIDs) are an emerging, powerful technology for precision CosmIC MICROWAVE Background (CMB) measurements, offering high sensitivity, ease of large-scale integration, and simplified readout architectures. In particular, polarization-sensitive KIDs operating at $90 \,{\text{G}}\text{Hz}$ achieve an optimal balance between atmospheric transparency, foreground contamination, and CMB sensitivity for ground-based observations. Here, we approach the specific problem of measuring the faint polarized signal of the CMB by means of simple and scalable detector arrays. We present simulations and preliminary measurements on a prototype $90 \,\text{G}\text{Hz}$ polarization-sensitive horn-coupled lumped element KID array, designed for ground-based CMB polarimeters. The detector array is made of a Ti–Al $10$ $+$ $30 \,\text{n}\text{m}$ thick bilayer, deposited on a Si substrate, designed to be operated at $150 \,\text{m}\text{K}$ . The KID layout has been optimized for absorption efficiency and polarization purity, as well as for high quality factor and multiplexing factor. The laboratory characterization, performed in a testbed dilution cryostat, includes the measurement of the critical temperature of the superconducting film, the dark responsivity and noise, and the quasi-particle lifetime.

Zitieren

APA

Nitto, I. D., Cacciotti, F., Bernardis, P. D., Coppolecchia, A., Lamagna, L., Masi, S., Paiella, A., Pettinari, G., & Volpe, A. (2026). Development of 90 GHz Polarization-Sensitive LEKIDs for CMB Experiments. IEEE Transactions on Applied Superconductivity, 36(6), 1-8. https://doi.org/10.1109/tasc.2026.3682965

Vancouver

Nitto ID, Cacciotti F, Bernardis PD, Coppolecchia A, Lamagna L, Masi S, et al. Development of 90 GHz Polarization-Sensitive LEKIDs for CMB Experiments. IEEE Transactions on Applied Superconductivity. 2026;36(6):1-8. doi:10.1109/tasc.2026.3682965

BibTeX
@article{Nitto2026,
  author = {Nitto, I. Di and Cacciotti, F. and Bernardis, P. de and Coppolecchia, A. and Lamagna, L. and Masi, S. and Paiella, A. and Pettinari, G. and Volpe, A.},
  title = {Development of 90 GHz Polarization-Sensitive LEKIDs for CMB Experiments},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {1--8},
  doi = {10.1109/tasc.2026.3682965}
}
Kostenlos starten →