Electromagnetic Optimization of Completely Open MRI Magnets With a Combination of Saddle-Shaped Coils and Circular Coils for Effective Magnetic Field Compensation

Yuya Asakura, Fumihiro Makiyama, Hiroshi Miyazaki

IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 4401906-4401906

DOI: 10.1109/tasc.2026.3682702 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von Yuya Asakura und 2 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional cylindrical MRI scanners can cause anxiety in patients given the restricted space, while existing open designs often compromise magnetic field performance. This paper presents the design and optimization of a novel, completely open MRI magnet system using high-temperature superconducting coils (REBCO produced by FUJIKURA) thus simultaneously ensuring both high patient accessibility and clinically relevant field characteristics. The proposed system features a unilateral magnet configuration with asymmetrically arranged saddle-shaped coils placed entirely beneath the patient bed. Although achieving both high field uniformity and strength is challenging in asymmetric configurations, the high critical current density of HTS allows for greater flexibility in coil placement, as strong magnetic fields can be generated from remote locations. A systematic, two-stage optimization strategy based on the simulated annealing algorithm was employed to design the magnet assembly, comprising primary saddle-shaped coils and a final circular correction coil. First, we obtained a coil arrangement that can generate a magnetic field strength of 0.323 T and a uniformity of 163 ppm using only a saddle-shaped coil. Next, three circular coils were added to correct the field, improving the uniformity to 99 ppm. Our computational study demonstrates the feasibility of a completely open HTS magnet that can alleviate patient claustrophobia without significantly compromising field quality, potentially expanding the clinical applications of MRI.

Zitieren

APA

Asakura, Y., Makiyama, F., & Miyazaki, H. (2026). Electromagnetic Optimization of Completely Open MRI Magnets With a Combination of Saddle-Shaped Coils and Circular Coils for Effective Magnetic Field Compensation. IEEE Transactions on Applied Superconductivity, 36(5), 4401906-4401906. https://doi.org/10.1109/tasc.2026.3682702

Vancouver

Asakura Y, Makiyama F, Miyazaki H. Electromagnetic Optimization of Completely Open MRI Magnets With a Combination of Saddle-Shaped Coils and Circular Coils for Effective Magnetic Field Compensation. IEEE Transactions on Applied Superconductivity. 2026;36(5):4401906-4401906. doi:10.1109/tasc.2026.3682702

BibTeX
@article{Asakura2026,
  author = {Asakura, Yuya and Makiyama, Fumihiro and Miyazaki, Hiroshi},
  title = {Electromagnetic Optimization of Completely Open MRI Magnets With a Combination of Saddle-Shaped Coils and Circular Coils for Effective Magnetic Field Compensation},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {4401906--4401906},
  doi = {10.1109/tasc.2026.3682702}
}
Kostenlos starten →