EUVIMEDEUVIMED entdecken
Crossref

Two-Step Nonlinear Calibration of LTS SQUID-Based Full Tensor Magnetic Gradient System

Tingli Liu, Longqing Qiu, Zhengwei Song, Jiawei Luo, Xingcheng Gong, Yuhong Cheng, Guofeng Zhang, Liangliang Rong

IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 1-9

DOI: 10.1109/tasc.2026.3679855 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von Tingli Liu und 7 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Gefördert von: Deep Earth Probe and Mineral Resources Exploration - National Science and Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The full tensor magnetic gradient (FTMG) system based on low-temperature superconducting quantum interference device (SQUID) planar gradiometers is susceptible to measurement errors, including imbalance errors, angular misalignment, scale factor deviations, and offset errors. To mitigate these effects, a two-step calibration method is proposed. In the first step, a three-dimensional Helmholtz coil generates a known magnetic field to correct imbalance and offset errors. In the second step, the FTMG module is rotated within a Maxwell coil to obtain outputs from all gradiometers. By minimizing the objective function between modeled and measured responses, the estimated error parameters can be obtained using the trust-region reflective (TRF) algorithm. Simulation results show that the mean absolute percentage error (MAPE) between the estimated and true parameters remains below 10%. Experimental validation further confirms the reliability of the method, as the residual magnetic gradient components for the six calibrated gradiometers are reduced from 688.16, 1017.32, 341.18, 532.45, 874.24, and 268.07 nT/m to 0.52, 0.30, 0.57, 0.35, 0.39, and 0.36 nT/m, respectively. These results demonstrate that the proposed approach significantly enhances the accuracy and stability of FTMG measurements.

Förderung

  • Deep Earth Probe and Mineral Resources Exploration - National Science and Technology

Zitieren

APA

Liu, T., Qiu, L., Song, Z., Luo, J., Gong, X., Cheng, Y., Zhang, G., & Rong, L. (2026). Two-Step Nonlinear Calibration of LTS SQUID-Based Full Tensor Magnetic Gradient System. IEEE Transactions on Applied Superconductivity, 36(5), 1-9. https://doi.org/10.1109/tasc.2026.3679855

Vancouver

Liu T, Qiu L, Song Z, Luo J, Gong X, Cheng Y, et al. Two-Step Nonlinear Calibration of LTS SQUID-Based Full Tensor Magnetic Gradient System. IEEE Transactions on Applied Superconductivity. 2026;36(5):1-9. doi:10.1109/tasc.2026.3679855

BibTeX
@article{Liu2026,
  author = {Liu, Tingli and Qiu, Longqing and Song, Zhengwei and Luo, Jiawei and Gong, Xingcheng and Cheng, Yuhong and Zhang, Guofeng and Rong, Liangliang},
  title = {Two-Step Nonlinear Calibration of LTS SQUID-Based Full Tensor Magnetic Gradient System},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {1--9},
  doi = {10.1109/tasc.2026.3679855}
}