Lab Characterization of the Soft X-Ray Transition Edge Spectrometer Sensor Array for the Advanced Photon Source
IEEE Transactions on Applied Superconductivity · 2026-09 · 36 (6) · 1-6
DOI: 10.1109/tasc.2026.3676364 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-09. Verfasst von Tejas Guruswamy und 8 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben. Gefördert von: U.S. DOE, Basic Energy Sciences.
Abstract (Originalsprache)
Soft X-ray resonant scattering is a sensitive probe of electronic, magnetic, and orbital order, but its weak signals are often embedded in substantial elastic, inelastic, and fluorescence backgrounds. In order to enable new science at the advanced photon source (APS) X-ray synchrotron, we have developed a transition edge sensor (TES) array-based spectrometer instrument optimized for energy-resolved detection in the 0.2- to 2-keV band, sustained operation at elevated photon count rates, and a mechanical design that allows for a small sensor–sample distance without interfering with existing hardware. The newly fabricated 256-pixel sensor array consists of sidecar Mo/Au TESs with Bi/Au absorbers, packaged onto a microsnout platform with frequency multiplexed µMux readout. We report on laboratory characterization of this array prior to final instrument integration and beamline deployment. DC current–voltage measurements establish acceptable uniformity and yield but identify a higher than intended bilayer critical temperature. Readout characterization shows the majority of µMux channels operating in a regime compatible with TES-limited energy resolution. Soft X-ray spectral measurements using a lab X-ray source demonstrate a full-width-at-half-maximum energy resolution median across the array of 2.3 eV at Al K$\alpha$ (1.5 keV), with almost 80% of all pixels producing spectra with resolution below 3 eV. The larger than targeted energy resolution is primarily attributed to a reduced resistance sensitivity to temperature ($\alpha$) relative to the prototype designs. Overall the results indicate the spectrometer meets the minimum requirements for resonant soft X-ray scattering and related measurements at the APS. Immediate next steps focus on commissioning of the instrument at the beamline, validation of high countrate operation, and establishment of energy calibration and data analysis workflows tailored to soft X-ray science.
Förderung
- U.S. DOE
- Basic Energy Sciences
Zitieren
APA
Guruswamy, T., Quaranta, O., Riekse, D., Panjaitan, J., Gades, L., Morgan, K., Weber, J., Swetz, D., & Miceli, A. (2026). Lab Characterization of the Soft X-Ray Transition Edge Spectrometer Sensor Array for the Advanced Photon Source. IEEE Transactions on Applied Superconductivity, 36(6), 1-6. https://doi.org/10.1109/tasc.2026.3676364
Vancouver
Guruswamy T, Quaranta O, Riekse D, Panjaitan J, Gades L, Morgan K, et al. Lab Characterization of the Soft X-Ray Transition Edge Spectrometer Sensor Array for the Advanced Photon Source. IEEE Transactions on Applied Superconductivity. 2026;36(6):1-6. doi:10.1109/tasc.2026.3676364
BibTeX
@article{Guruswamy2026,
author = {Guruswamy, Tejas and Quaranta, Orlando and Riekse, Danielle and Panjaitan, Jad and Gades, Lisa and Morgan, Kelsey and Weber, Joel and Swetz, Daniel and Miceli, Antonino},
title = {Lab Characterization of the Soft X-Ray Transition Edge Spectrometer Sensor Array for the Advanced Photon Source},
journal = {IEEE Transactions on Applied Superconductivity},
year = {2026},
volume = {36},
number = {6},
pages = {1--6},
doi = {10.1109/tasc.2026.3676364}
}
EUVIMED