EUVIMEDEUVIMED entdecken
Crossref

Wafer-Scale Low-Temperature Measurements of Transition-Edge Sensors during Fabrication

Joel C. Weber, Jason E. Nobles, Robinjeet Singh, Avirup Roy, Kelsey M. Morgan, Nathan J. Ortiz, Jeff Van Lanen, Kyuyoung Bae, Shannon M. Duff, Daniel S. Swetz, Galen C. O'Neil, Joel N. Ullom und 1 weitere

IEEE Transactions on Applied Superconductivity · 2026-09 · 36 (6) · 1-5

DOI: 10.1109/tasc.2026.3676333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-09. Verfasst von Joel C. Weber und 12 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben. Gefördert von: Advanced Research Projects Agency-Energy, U.S. Department of Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of large-scale, high-resolution transition-edge sensor (TES) arrays requires precise, wafer-scale control of the superconducting critical temperature ( T c ). For microcalorimeters, this is often achieved with a superconductor-normal metal bilayer where the thickness ratio between the two materials determines T c through the proximity effect. Reliably achieving a specific T c across multiple wafers with good uniformity remains challenging as the fabrication process is highly sensitive to substrate quality, deposition parameters, and deposited thin-film thickness. Missing a T c target results in an array with degraded or unusable performance and wastes fabrication/measurement resources. To help solve these limitations with TES microcalorimeter fabrication, we have developed a method of measuring 76.2 mm wafers after bilayer deposition to screen for T c accuracy and uniformity. Four-wire resistance measurements of test structures across the wafer provide rapid feedback early in the fabrication process at temperatures down to 20 mK. We leverage the hybrid additive-subtractive TES process to screen TES arrays with multiple T c values on a single wafer comprised of a single bilayer. After measurement, the bilayer normal metal thickness can be increased with an additional evaporation step to lower T c or decreased with an ion mill step to raise T c as needed. We also present a design to expand measurement capability to 150 mm wafers to screen both larger microcalorimeter arrays as well as NIST cosmic microwave background TES bolometer arrays.

Förderung

  • Advanced Research Projects Agency-Energy
  • U.S. Department of Energy

Zitieren

APA

Weber, J. C., Nobles, J. E., Singh, R., Roy, A., Morgan, K. M., Ortiz, N. J., Lanen, J. V., Bae, K., Duff, S. M., Swetz, D. S., O'Neil, G. C., Ullom, J. N., & Schmidt, D. R. (2026). Wafer-Scale Low-Temperature Measurements of Transition-Edge Sensors during Fabrication. IEEE Transactions on Applied Superconductivity, 36(6), 1-5. https://doi.org/10.1109/tasc.2026.3676333

Vancouver

Weber JC, Nobles JE, Singh R, Roy A, Morgan KM, Ortiz NJ, et al. Wafer-Scale Low-Temperature Measurements of Transition-Edge Sensors during Fabrication. IEEE Transactions on Applied Superconductivity. 2026;36(6):1-5. doi:10.1109/tasc.2026.3676333

BibTeX
@article{Weber2026,
  author = {Weber, Joel C. and Nobles, Jason E. and Singh, Robinjeet and Roy, Avirup and Morgan, Kelsey M. and Ortiz, Nathan J. and Lanen, Jeff Van and Bae, Kyuyoung and Duff, Shannon M. and Swetz, Daniel S. and O'Neil, Galen C. and Ullom, Joel N. and Schmidt, Daniel R.},
  title = {Wafer-Scale Low-Temperature Measurements of Transition-Edge Sensors during Fabrication},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {1--5},
  doi = {10.1109/tasc.2026.3676333}
}
Kostenlos starten →