20 Years of TES Gamma-Ray Microcalorimeters
IEEE Transactions on Applied Superconductivity · 2026-09 · 36 (6) · 1-8
DOI: 10.1109/tasc.2026.3674735 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-09. Verfasst von Shannon E. Kossmann und 1 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben.
Abstract (Originalsprache)
In the last 20 years, transition edge sensor (TES) gamma-ray microcalorimeters have evolved from the first proof of concept single pixel detectors to large, multiplexed arrays of hundreds of TES pixels used to collect ultra-high resolution gamma spectra. For example, the spectrometer optimized for facility integrated applications detector of 256 pixels is able to achieve coadded spectra with resolution as good as 59 eV full width at half maximum (FWHM) at 97 keV or 70–90 eV FWHM for high-rate plutonium measurements. Much of the research and development of these detectors over the last 20 years has focused on improving the achieved resolution of individual TES pixels, creating arrays with a sufficiently high yield of pixels, developing methods to readout large numbers of individual pixels in an array without providing too much heat load at the very cold temperatures (from wires to room temperature), how to process the data from each TES individually, and how to calibrate and coadd the pixel data to form a spectrum without much degradation of resolution. TES gamma-ray microcalorimeter arrays are now used for improvement of fundamental nuclear data and to collect ultra-high-resolution spectra that can resolve peaks that overlap in high purity germanium (HPGe) spectra for better characterization of nuclear material. Current areas of development include increasing the size of arrays with new form factors, improving user experience with more mature systems, integration of these detector systems into facilities with nuclear material to improve nuclear material control and accounting with significantly improved resolution of complex spectra compared to HPGe detectors, and ongoing research and alteration of the TES detector design.
Zitieren
APA
Kossmann, S. E., & Croce, M. P. (2026). 20 Years of TES Gamma-Ray Microcalorimeters. IEEE Transactions on Applied Superconductivity, 36(6), 1-8. https://doi.org/10.1109/tasc.2026.3674735
Vancouver
Kossmann SE, Croce MP. 20 Years of TES Gamma-Ray Microcalorimeters. IEEE Transactions on Applied Superconductivity. 2026;36(6):1-8. doi:10.1109/tasc.2026.3674735
BibTeX
@article{Kossmann2026,
author = {Kossmann, Shannon E. and Croce, Mark P.},
title = {20 Years of TES Gamma-Ray Microcalorimeters},
journal = {IEEE Transactions on Applied Superconductivity},
year = {2026},
volume = {36},
number = {6},
pages = {1--8},
doi = {10.1109/tasc.2026.3674735}
}
EUVIMED