EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Critical Current and Magnetization Scaling of Nb 3 Sn Wires: Measurements and Simulations from Exact Wire Geometries

Josef Baumann, Simon C. Hopkins, Julien Dular, Fredrik Magnus, Mariusz Wozniak, Jeroen D. Bijlsma, Bentejui Medina-Clavijo, Thierry Boutboul

IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 1-9

DOI: 10.1109/tasc.2026.3674540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von Josef Baumann und 7 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CERN’s High Field Magnet.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the context of the High Field Magnet (HFM) program, 14 T dipole magnets are under development towards requirements for a proposed Future Circular Collider (FCC-hh). For evaluation of operating margins, a reliable critical current density scaling, J c ( B , T ), is required up to 18 T and for 1.9–10 K; whilst AC loss calculations for designing cooling and quench protection schemes require this to be extended down to an injection field of ∼1 T or below at the operating temperature. Scaling laws for Nb 3 Sn wires have been extensively studied in the literature. However, for practical high I c wires, it is rarely possible to access this full temperature and field range in measurements with a transport current, and a variety of procedural methodologies have been proposed to address divergences between transport and magnetization measurements. In this study, a recently-developed Coupled Axial and Transverse Currents (CATI) finite element method is applied for modeling the electrical and magnetic behavior of the RRP Nb 3 Sn wire used for HL-LHC MQXF magnets, incorporating its exact twisted composite geometry as parameterized by image analysis. Fitting parameters for the J c ( B , T ) of the superconductor are found to simultaneously match transport I c (6–15 T, 1.9 K and 4.3 K) and magnetization (0–10 T, 1.9–16 K), and the assumptions required are discussed. The model is then used to explore the validity of common procedures applied to experimental data, including self-field correction and procedural fitting approaches.

Förderung

  • CERN’s High Field Magnet

Zitieren

APA

Baumann, J., Hopkins, S. C., Dular, J., Magnus, F., Wozniak, M., Bijlsma, J. D., Medina-Clavijo, B., & Boutboul, T. (2026). Critical Current and Magnetization Scaling of Nb 3 Sn Wires: Measurements and Simulations from Exact Wire Geometries. IEEE Transactions on Applied Superconductivity, 36(5), 1-9. https://doi.org/10.1109/tasc.2026.3674540

Vancouver

Baumann J, Hopkins SC, Dular J, Magnus F, Wozniak M, Bijlsma JD, et al. Critical Current and Magnetization Scaling of Nb 3 Sn Wires: Measurements and Simulations from Exact Wire Geometries. IEEE Transactions on Applied Superconductivity. 2026;36(5):1-9. doi:10.1109/tasc.2026.3674540

BibTeX
@article{Baumann2026,
  author = {Baumann, Josef and Hopkins, Simon C. and Dular, Julien and Magnus, Fredrik and Wozniak, Mariusz and Bijlsma, Jeroen D. and Medina-Clavijo, Bentejui and Boutboul, Thierry},
  title = {Critical Current and Magnetization Scaling of Nb 3 Sn Wires: Measurements and Simulations from Exact Wire Geometries},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {1--9},
  doi = {10.1109/tasc.2026.3674540}
}
Kostenlos starten →