Transient Analyses for the ASTERICS 28 GHz ECR Ion Source Superconducting Magnet

T. Cadoux, T. Lemercier, C. Pucheu-Plante, D. Simon, H. Allain, C. Berriaud, H. Felice, P. Graffin, V. Kleymenov, A. Sinanna, F. Stacchi, R. Touzery und 3 weitere

IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 1-6

DOI: 10.1109/tasc.2026.3670817 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von T. Cadoux und 14 weiteren Autor:innen. Die Arbeit nennt 7 Literaturangaben. Gefördert von: french “Agence Nationale de la Recherche.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A superconducting 28 GHz ECR (Electron Cyclotron Resonance) ion source, named ASTERICS, is currently being developed as part of the NEWGAIN project (NEW GAnil INjector). The NEWGAIN project aims to equip the SPIRAL2 LINAC at GANIL with a new injector capable of producing very intense heavy-ion beams, up to uranium, well beyond the performance of GANIL’s existing injectors. For the ASTERICS ion source, CEA is designing a superconducting magnet consisting of a sextupole surrounded by three solenoids to confine the plasma. The design is now well advanced, and the magnet will be manufactured in the industry. During the design phase, CEA conducted several analyses to investigate transient phenomena that may occur in the event of a quench. These studies focused mainly on magnet protection and the development of eddy currents within the thermal screen. For the protection and for the eddy-currents analyses, the simulations have been performed with the transient and multiphysics modules of Opera. These analyses allow us to validate the choices that have been made for the magnet protection and stress the importance to take into account the quench phenomena on the thermomechanical design of the thermal screen and the choice of materials and geometry. This paper will present these analyses along with an update on the ASTERICS ion source development.

Förderung

  • french “Agence Nationale de la Recherche

Zitieren

APA

Cadoux, T., Lemercier, T., Pucheu-Plante, C., Simon, D., Allain, H., Berriaud, C., Felice, H., Graffin, P., Kleymenov, V., Sinanna, A., Stacchi, F., Touzery, R., Trieste, S., Carbonell, R. V., & Thuillier, T. (2026). Transient Analyses for the ASTERICS 28 GHz ECR Ion Source Superconducting Magnet. IEEE Transactions on Applied Superconductivity, 36(5), 1-6. https://doi.org/10.1109/tasc.2026.3670817

Vancouver

Cadoux T, Lemercier T, Pucheu-Plante C, Simon D, Allain H, Berriaud C, et al. Transient Analyses for the ASTERICS 28 GHz ECR Ion Source Superconducting Magnet. IEEE Transactions on Applied Superconductivity. 2026;36(5):1-6. doi:10.1109/tasc.2026.3670817

BibTeX
@article{Cadoux2026,
  author = {Cadoux, T. and Lemercier, T. and Pucheu-Plante, C. and Simon, D. and Allain, H. and Berriaud, C. and Felice, H. and Graffin, P. and Kleymenov, V. and Sinanna, A. and Stacchi, F. and Touzery, R. and Trieste, S. and Carbonell, R. Vallcorba and Thuillier, T.},
  title = {Transient Analyses for the ASTERICS 28 GHz ECR Ion Source Superconducting Magnet},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {1--6},
  doi = {10.1109/tasc.2026.3670817}
}