EUVIMEDEUVIMED entdecken
Crossref

Analyzing Parameter Changes and Performance Degradation of a Non-Insulated 1T-HTS Magnet After One Year of Operation in a Test Facility

Sebastian Hellmann, Jakub Glowacki, Nicholas M. Strickland, Randy Pollock

IEEE Transactions on Applied Superconductivity · 2026-08 · 36 (5) · 1-5

DOI: 10.1109/tasc.2026.3670788 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2026-08. Verfasst von Sebastian Hellmann und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Non-insulated HTS magnets can provide significant advantages over conventional HTS or LTS magnets. These can be their self-protecting properties, provided by possible radial current flow in the magnet coils, their high mechanical stability or the possibility for a high overall current density in the magnet windings. In recent years many research efforts were devoted to non-insulated HTS coils. However, not much work has been published on long-term performance and degradation mechanisms. In this paper we introduce a non-insulated HTS magnet that was designed and built at the Paihau - Robinson Research Institute as part of a test facility for applied-field magneto-plasmadynamic thrusters for space applications. So far, this magnet has been in operation for more than one year. During that time, it went through more than 51 thermal cycles between room temperature and its designed operation temperature of ∼65 K. It also has undergone more than 350 power cycles with some exceeding the design value of 1 T by up to 25%. We present a detailed analysis of the magnet parameters at the start of operation in the test facility. These parameters include room temperature resistance measurements, in-situ measurements of the individual magnet coils, remanent resistance measurements at 65 K and measurements of the characteristic resistance Rc. We further discuss possible signs and mechanisms of magnet degradation.

Zitieren

APA

Hellmann, S., Glowacki, J., Strickland, N. M., & Pollock, R. (2026). Analyzing Parameter Changes and Performance Degradation of a Non-Insulated 1T-HTS Magnet After One Year of Operation in a Test Facility. IEEE Transactions on Applied Superconductivity, 36(5), 1-5. https://doi.org/10.1109/tasc.2026.3670788

Vancouver

Hellmann S, Glowacki J, Strickland NM, Pollock R. Analyzing Parameter Changes and Performance Degradation of a Non-Insulated 1T-HTS Magnet After One Year of Operation in a Test Facility. IEEE Transactions on Applied Superconductivity. 2026;36(5):1-5. doi:10.1109/tasc.2026.3670788

BibTeX
@article{Hellmann2026,
  author = {Hellmann, Sebastian and Glowacki, Jakub and Strickland, Nicholas M. and Pollock, Randy},
  title = {Analyzing Parameter Changes and Performance Degradation of a Non-Insulated 1T-HTS Magnet After One Year of Operation in a Test Facility},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2026},
  volume = {36},
  number = {5},
  pages = {1--5},
  doi = {10.1109/tasc.2026.3670788}
}
Kostenlos starten →