EUVIMEDEUVIMED entdecken
Crossref

AC Loss Characteristics of a Double Pancake Coil Wound With Multifilamentary REBCO Tape With High Inter-Filament Resistance

Ryoma Oishi, Koudai Jingami, Yuji Nishida, Yuuki Himeno, Ryota Kashiwagi, Hiromasa Sasa, Koichi Yoshida, Hiroshi Miyazaki, Masataka Iwakuma, Hishiro T. Hirose, Teruo Izumi, Takato Machi und 1 weitere

IEEE Transactions on Applied Superconductivity · 2025-08 · 35 (5) · 1-6

DOI: 10.1109/tasc.2025.3525599 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2025-08. Verfasst von Ryoma Oishi und 12 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: New Energy and Industrial Technology Development Organization, Graduate School of ISEE of Kyushu University for Supporting Students’ Participation in International Conferences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reducing AC loss in superconducting AC equipment is crucial because of its substantial contribution to the cryogenic load. Decreasing the filament width can mitigate hysteresis loss of REBa2Cu3O7−δ (REBCO, RE = rare earth elements) superconducting tapes, and segmenting the superconducting layer into multiple filaments is a viable reduction approach. However, filaments tend to connect when the inter-filament resistance is low. Therefore, we propose Cut and Aggregated Multifilamentary (CaAM) tapes with high inter-filament resistance achieved via the electrodeposition of polyimide across the entire tape. This tape configuration involves aligning four 1-mm-wide filaments in parallel and bonding them onto a polyimide substrate. AC loss measurements of short tapes exhibit a reduction at high magnetic fields. Additionally, we fabricated double pancake coils, each coil contained 80$\ \times $ 2 turns, wound with monofilament tape and CaAM tape (coils A and B, respectively) and assessed the AC loss of the fabricated coils in liquid nitrogen. Experimental results indicate that the AC loss of coil B, using CaAM tape, is greater than that of coil A in the low-current region. However, they are almost identical in the high-current region. In contrast to the multifilament tapes with low inter-filament resistance, CaAM tapes indicate the possibility of loss reduction when used in coils.

Förderung

  • New Energy and Industrial Technology Development Organization
  • Graduate School of ISEE of Kyushu University for Supporting Students’ Participation in International Conferences

Zitieren

APA

Oishi, R., Jingami, K., Nishida, Y., Himeno, Y., Kashiwagi, R., Sasa, H., Yoshida, K., Miyazaki, H., Iwakuma, M., Hirose, H. T., Izumi, T., Machi, T., & Nakamura, M. (2025). AC Loss Characteristics of a Double Pancake Coil Wound With Multifilamentary REBCO Tape With High Inter-Filament Resistance. IEEE Transactions on Applied Superconductivity, 35(5), 1-6. https://doi.org/10.1109/tasc.2025.3525599

Vancouver

Oishi R, Jingami K, Nishida Y, Himeno Y, Kashiwagi R, Sasa H, et al. AC Loss Characteristics of a Double Pancake Coil Wound With Multifilamentary REBCO Tape With High Inter-Filament Resistance. IEEE Transactions on Applied Superconductivity. 2025;35(5):1-6. doi:10.1109/tasc.2025.3525599

BibTeX
@article{Oishi2025,
  author = {Oishi, Ryoma and Jingami, Koudai and Nishida, Yuji and Himeno, Yuuki and Kashiwagi, Ryota and Sasa, Hiromasa and Yoshida, Koichi and Miyazaki, Hiroshi and Iwakuma, Masataka and Hirose, Hishiro T. and Izumi, Teruo and Machi, Takato and Nakamura, Miyuki},
  title = {AC Loss Characteristics of a Double Pancake Coil Wound With Multifilamentary REBCO Tape With High Inter-Filament Resistance},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2025},
  volume = {35},
  number = {5},
  pages = {1--6},
  doi = {10.1109/tasc.2025.3525599}
}
Kostenlos starten →