EUVIMEDEUVIMED entdecken
Crossref

Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier

M. A. Castellanos-Beltran, L. Howe, A. Giachero, M. R. Vissers, D. Labranca, J. N. Ullom, P. F. Hopkins

IEEE Transactions on Applied Superconductivity · 2025-08 · 35 (5) · 1-5

DOI: 10.1109/tasc.2024.3525451 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Applied Superconductivity, 2025-08. Verfasst von M. A. Castellanos-Beltran und 6 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing the size and complexity of quantum information systems requires highly-multiplexed readout architectures, as well as amplifier chains operating near the quantum limit (QL) of added noise. While documented prior efforts in KI-TWPA integration in quantum systems are scarce, in this work we demonstrate integration of a KI-TWPA with a multiplexed-qubit device. To quantify the system noise improvement we perform an ac Stark shift calibration to precisely determine noise power levels on-chip (at each cavity's reference plane) and the total system gain. We then characterize the qubit state measurement fidelity and the corresponding signal-to-noise ratio (SNR). To conduct the most faithful measurement of the benefits offered by the KI-TWPA we perform these measurements for readout chains where the high electron mobility transistor (HEMT) amplifier is the first-stage amplifier (FSA) – with none of the external hardware required to operate the KI-TWPA – and with the KI-TWPA as the FSA. While some readout cavities fall outside the KI-TWPA bandwidth, for those inside the bandwidth we demonstrate a maximum improvement in the state measurement SNR by a factor of 1.45, and increase the fidelity from 96.2% to 97.8%. These measurements demonstrate a system noise below 5 quanta referenced on-chip and we bound the KI-TWPA excess noise to be below 4 quanta for the six cavities inside its bandwidth. These results show a promising path forward for realizing quantum-limited readout chains in large qubit systems using a single parametric amplifier.

Zitieren

APA

Castellanos-Beltran, M. A., Howe, L., Giachero, A., Vissers, M. R., Labranca, D., Ullom, J. N., & Hopkins, P. F. (2025). Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier. IEEE Transactions on Applied Superconductivity, 35(5), 1-5. https://doi.org/10.1109/tasc.2024.3525451

Vancouver

Castellanos-Beltran MA, Howe L, Giachero A, Vissers MR, Labranca D, Ullom JN, et al. Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier. IEEE Transactions on Applied Superconductivity. 2025;35(5):1-5. doi:10.1109/tasc.2024.3525451

BibTeX
@article{CastellanosBeltran2025,
  author = {Castellanos-Beltran, M. A. and Howe, L. and Giachero, A. and Vissers, M. R. and Labranca, D. and Ullom, J. N. and Hopkins, P. F.},
  title = {Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier},
  journal = {IEEE Transactions on Applied Superconductivity},
  year = {2025},
  volume = {35},
  number = {5},
  pages = {1--5},
  doi = {10.1109/tasc.2024.3525451}
}
Kostenlos starten →