A Compact Dual-Band Implantable MIMO Antenna for Wireless Capsule Endoscopy
IEEE Transactions on Antennas and Propagation · 2024-10 · 72 (10) · 7515-7524
DOI: 10.1109/tap.2024.3454434 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Antennas and Propagation, 2024-10. Verfasst von Amjad Iqbal und 4 weiteren Autor:innen. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Royal Society through the Newton International Fellowship.
Abstract (Originalsprache)
This article introduces a compact dual-element multiple-input multiple-output (MIMO) implantable antenna for high-data-rate wireless capsule endoscopy (WCE) applications. The proposed antenna works at 915 and 2450 MHz with the respective fractional bandwidths (FBWs) of 23.6% and 12.14%. The two-port MIMO system consists of two triangular-shaped radiators arranged face-to-face, forming a square configuration. The edge-to-edge distance between the radiators is 0.3 mm, indicating that the radiating elements are placed extremely close to each other. Three semicircular slots, three edge slots in the patch, a conducting via in each patch, and a high permittivity substrate are utilized to reduce the antenna’s volume ( $9.8\times 9.8\times 0.3=28.81$ mm3). To minimize electromagnetic (EM) coupling between both patches, a diagonal slot measuring $12.5\times 0.3$ mm2 is etched in the ground plane, and a 6.5-nH inductor is added between the radiating patches. As a result, the mutual coupling values of −35.85 and −31.6 dB are observed at 915 and 2450 MHz, respectively. The effectiveness of the MIMO system is validated through the analysis of specific absorption rate (SAR) and link budget performance, both showing satisfactory results. With an input power of 1 W, the maximum SAR is 41.2 W/kg for 915 MHz and 43.2 W/kg for 2450 MHz. Channel parameters for the $2\times 2$ MIMO configuration are calculated and validated, showing a channel capacity of 9.1 bps/Hz at SNR =20 dB. A prototype is developed and tested in the minced pork to validate simulations. Based on the results and performance, the proposed MIMO antenna system demonstrates high potential for high-data-rate capsule endoscopes.
Förderung
- Royal Society through the Newton International Fellowship
Zitieren
APA
Iqbal, A., Kiani, S. H., Al-Hasan, M., Mabrouk, I. B., & Denidni, T. A. (2024). A Compact Dual-Band Implantable MIMO Antenna for Wireless Capsule Endoscopy. IEEE Transactions on Antennas and Propagation, 72(10), 7515-7524. https://doi.org/10.1109/tap.2024.3454434
Vancouver
Iqbal A, Kiani SH, Al-Hasan M, Mabrouk IB, Denidni TA. A Compact Dual-Band Implantable MIMO Antenna for Wireless Capsule Endoscopy. IEEE Transactions on Antennas and Propagation. 2024;72(10):7515-7524. doi:10.1109/tap.2024.3454434
BibTeX
@article{Iqbal2024,
author = {Iqbal, Amjad and Kiani, Saad Hassan and Al-Hasan, Muath and Mabrouk, Ismail Ben and Denidni, Tayeb A.},
title = {A Compact Dual-Band Implantable MIMO Antenna for Wireless Capsule Endoscopy},
journal = {IEEE Transactions on Antennas and Propagation},
year = {2024},
volume = {72},
number = {10},
pages = {7515--7524},
doi = {10.1109/tap.2024.3454434}
}
EUVIMED