Label-Free D-Mannitol Detection Using Vanadium Dioxide and TMDCs-Based Metallic Plasmonic Biosensor

Mogal Mahazira Tabassum, Yesudasu Vasimalla, Madhusudan Mishra, Santosh Kumar

IEEE Transactions on AgriFood Electronics · 2026-03 · 4 (1) · 168-175

DOI: 10.1109/tafe.2025.3622866 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on AgriFood Electronics, 2026-03. Verfasst von Mogal Mahazira Tabassum und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Koneru Lakshmaiah Education Foundation, India.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Identification of biomolecules such as D-mannitol is required for biotechnology, environmental monitoring, and medical diagnosis. This study presents a customized surface plasmon resonance (SPR) sensor that uses vanadium dioxide ( $\mathrm{V}{{\mathrm{O}}_2}$ ) as an important material layer to improve detection performance. To improve its performance, the suggested sensor has a layered structure that is composed of transition metal dichalcogenides, Pilkington Optiwhite glass, and a silver (Ag) layer. D-mannitol detection sensitivity and uniqueness increase with $\mathrm{V}{{\mathrm{O}}_2}$ and special optical and plasmonic characteristics. Our experiments show that the suggested sensor performs better than the conventional SPR sensor, with a high sensitivity of 300.41 $^\circ /\text{RIU}$ , figure of merit of 68.96 $\text{RI}{{\mathrm{U}}^{ - 1}}$ , combined sensitive factor of 67.633, and a quality factor of 200.1248 $\text{RI}{{\mathrm{U}}^{ - 1}}$ . Label-free, in real-time biosensing applications, the work displays the ability of $\mathrm{V}{{\mathrm{O}}_2}$ , which provides a promising development in highly sensitive identification methods. In addition, a comparison exam shows the better performance of our sensors on current detection techniques. Finally, the construction methods that will help to make the suggested sensor experimentally.

Förderung

  • Koneru Lakshmaiah Education Foundation, India

Zitieren

APA

Tabassum, M. M., Vasimalla, Y., Mishra, M., & Kumar, S. (2026). Label-Free D-Mannitol Detection Using Vanadium Dioxide and TMDCs-Based Metallic Plasmonic Biosensor. IEEE Transactions on AgriFood Electronics, 4(1), 168-175. https://doi.org/10.1109/tafe.2025.3622866

Vancouver

Tabassum MM, Vasimalla Y, Mishra M, Kumar S. Label-Free D-Mannitol Detection Using Vanadium Dioxide and TMDCs-Based Metallic Plasmonic Biosensor. IEEE Transactions on AgriFood Electronics. 2026;4(1):168-175. doi:10.1109/tafe.2025.3622866

BibTeX
@article{Tabassum2026,
  author = {Tabassum, Mogal Mahazira and Vasimalla, Yesudasu and Mishra, Madhusudan and Kumar, Santosh},
  title = {Label-Free D-Mannitol Detection Using Vanadium Dioxide and TMDCs-Based Metallic Plasmonic Biosensor},
  journal = {IEEE Transactions on AgriFood Electronics},
  year = {2026},
  volume = {4},
  number = {1},
  pages = {168--175},
  doi = {10.1109/tafe.2025.3622866}
}
Kostenlos starten →