Fachartikel in der Zeitschrift IEEE Open Journal of Instrumentation and Measurement, 2026. Verfasst von Daniele Faggi und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: IPCEI-CIS project “Villanova”.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Qualifying the metrological properties of an AI-based Internet of Things (IoT) sensor system requires explicit identification of the measurands, characterization of uncertainty sources following established metrological principles, and on-device validation against a trusted desktop reference. Hybrid convolutional neural network–Kolmogorov–Arnold network (CNN-KAN) models can be deployed on microcontrollers after operator decomposition, yet the impact of sensor-system factors on end-to-end measurement uncertainty remains uncharacterised. This article presents a systematic evaluation of a dual-tier IoT architecture (XIAO ESP32S3 Sense edge node and Raspberry Pi 3 gateway) with explicit uncertainty quantification for all measurements. Four measurands are defined and characterized: 1) on-device inference latency [s]; 2) on-device classification accuracy [%]; 3) CPU junction temperature [°C]; and 4) desktop-to-device accuracy gap [pp]. We quantify four system-level effects neglected by model-centric studies: 1) TensorFlow lite (TFLite) Microruntime selection introduces a $4.3\times $ latency variation (±3% relative uncertainty), a pure measurement variability component; 2) a per-channel versus per-tensor quantization mismatch causes a silent 1.8 pp accuracy drop (95% CI ±0.2 pp), a systematic bias that was detected and corrected; 3) compiler optimization flags yield a deterministic $1.82\times $ speedup without accuracy change; and 4) sustained-inference thermal throttling adds 7%–9% latency [±1.5% interquartile range (IQR)], a measurement drift effect. We explicitly distinguish between systematic errors, random variability, and drift. All experimental procedures, repeatability metrics, and source code are publicly available to ensure traceability and reproducibility. These findings demonstrate that runtime, toolchain, and quantization handling are first-order parameters that dominate model-level design choices and must be accompanied by measurement uncertainty budgets in systematic bias-aware AI deployments.

Förderung

  • IPCEI-CIS project “Villanova”

Zitieren

APA

Faggi, D., Kuznetsov, O., & Frontoni, E. (2026). Sensor-System Characterization of CNN-KAN Person Detection on Dual-Tier IoT Platforms With Uncertainty Quantification. IEEE Open Journal of Instrumentation and Measurement, 5, 2500507-2500507. https://doi.org/10.1109/ojim.2026.3712887

Vancouver

Faggi D, Kuznetsov O, Frontoni E. Sensor-System Characterization of CNN-KAN Person Detection on Dual-Tier IoT Platforms With Uncertainty Quantification. IEEE Open Journal of Instrumentation and Measurement. 2026;5:2500507-2500507. doi:10.1109/ojim.2026.3712887

BibTeX
@article{Faggi2026,
  author = {Faggi, Daniele and Kuznetsov, Oleksandr and Frontoni, Emanuele},
  title = {Sensor-System Characterization of CNN-KAN Person Detection on Dual-Tier IoT Platforms With Uncertainty Quantification},
  journal = {IEEE Open Journal of Instrumentation and Measurement},
  year = {2026},
  volume = {5},
  pages = {2500507--2500507},
  doi = {10.1109/ojim.2026.3712887}
}
Kostenlos starten →