EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Simulation of Image-Guided Microwave Ablation Therapy Using a Digital Twin Computational Model

Frankangel Servin iD, Jarrod A Collins iD, Jon S Heiselman iD, Katherine C Frederick-Dyer iD, Virginia B Planz iD, Sunil K Geevarghese iD, Daniel B Brown, William R Jarnagin iD, Michael I Miga iD

IEEE Open Journal of Engineering in Medicine and Biology · 2024 · 5 · 107-124

DOI: 10.1109/ojemb.2023.3345733 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Open Journal of Engineering in Medicine and Biology, 2024. Verfasst von Frankangel Servin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical EngineeringVanderbilt University Nashville TN 37235 USA. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 118 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS, Vanderbilt University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Emerging computational tools such as healthcare digital twin modeling are enabling the creation of patient-specific surgical planning, including microwave ablation to treat primary and secondary liver cancers. Healthcare digital twins (DTs) are anatomically one-to-one biophysical models constructed from structural, functional, and biomarker-based imaging data to simulate patient-specific therapies and guide clinical decision-making. In microwave ablation (MWA), tissue-specific factors including tissue perfusion, hepatic steatosis, and fibrosis affect therapeutic extent, but current thermal dosing guidelines do not account for these parameters. This study establishes an MR imaging framework to construct three-dimensional biophysical digital twins to predict ablation delivery in livers with 5 levels of fat content in the presence of a tumor. Four microwave antenna placement strategies were considered, and simulated microwave ablations were then performed using 915 MHz and 2450 MHz antennae in Tumor Naïve DTs (control), and Tumor Informed DTs at five grades of steatosis. Across the range of fatty liver steatosis grades, fat content was found to significantly increase ablation volumes by approximately 29-l42% in the Tumor Naïve and 55-60% in the Tumor Informed DTs in 915 MHz and 2450 MHz antenna simulations. The presence of tumor did not significantly affect ablation volumes within the same steatosis grade in 915 MHz simulations, but did significantly increase ablation volumes within mild-, moderate-, and high-fat steatosis grades in 2450 MHz simulations. An analysis of signed distance to agreement for placement strategies suggests that accounting for patient-specific tumor tissue properties significantly impacts ablation forecasting for the preoperative evaluation of ablation zone coverage.

Schlagwörter

Stichwörter der Autor:innen

Computational modeldigital twinfatty liver diseasefinite elementliver cancermicrowave ablation

Autor:innen und Institutionen

  • Department of Biomedical EngineeringVanderbilt University Nashville TN 37235 USA.
  • Vanderbilt Institute for Surgery and EngineeringVanderbilt University Nashville TN 37235 USA.
  • Department of Surgery, Hepatopancreatobiliary ServiceMemorial Sloan Kettering Cancer Center New York NY 10065 USA.
  • Department of RadiologyVanderbilt University Medical Center Nashville TN 37235 USA.
  • Department of SurgeryVanderbilt University Medical Center Nashville TN 37235 USA.
  • Department of Neurological SurgeryVanderbilt University Medical Center Nashville TN 37235 USA.

ORCID-Profile: Frankangel Servin, Jarrod A Collins, Jon S Heiselman, Katherine C Frederick-Dyer, Virginia B Planz, Sunil K Geevarghese, William R Jarnagin, Michael I Miga

Förderung

  • NCI NIH HHS
  • NIBIB NIH HHS
  • Vanderbilt University
  • Memorial Sloan-Kettering Cancer Center

Zitieren

APA

Servin, F., Collins, J. A., Heiselman, J. S., Frederick-Dyer, K. C., Planz, V. B., Geevarghese, S. K., Brown, D. B., Jarnagin, W. R., & Miga, M. I. (2024). Simulation of Image-Guided Microwave Ablation Therapy Using a Digital Twin Computational Model. IEEE Open Journal of Engineering in Medicine and Biology, 5, 107-124. https://doi.org/10.1109/ojemb.2023.3345733

Vancouver

Servin F, Collins JA, Heiselman JS, Frederick-Dyer KC, Planz VB, Geevarghese SK, et al. Simulation of Image-Guided Microwave Ablation Therapy Using a Digital Twin Computational Model. IEEE Open Journal of Engineering in Medicine and Biology. 2024;5:107-124. doi:10.1109/ojemb.2023.3345733

BibTeX
@article{Servin2024,
  author = {Servin, Frankangel and Collins, Jarrod A and Heiselman, Jon S and Frederick-Dyer, Katherine C and Planz, Virginia B and Geevarghese, Sunil K and Brown, Daniel B and Jarnagin, William R and Miga, Michael I},
  title = {Simulation of Image-Guided Microwave Ablation Therapy Using a Digital Twin Computational Model},
  journal = {IEEE Open Journal of Engineering in Medicine and Biology},
  year = {2024},
  volume = {5},
  pages = {107--124},
  doi = {10.1109/ojemb.2023.3345733}
}
Kostenlos starten →