EUVIMEDEUVIMED entdecken
Crossref

ReTeNet: A Residual Encoder and Transformer Encoders Network for Stress Monitoring From Wearable Device

Md Santo Ali, Mohammod Abdul Motin, Sumaiya Kabir

IEEE Signal Processing Letters · 2025 · 32 · 3635-3639

DOI: 10.1109/lsp.2025.3607767 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Signal Processing Letters, 2025. Verfasst von Md Santo Ali und 2 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: University Grants Commission, Bangladesh, and Rajshahi University of Engineering & Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mental stress adversely impacts overall well-being, and chronic stress poses serious risks to both physical and mental health, necessitating the development of wearable-based stress monitoring tools. Blood volume pulse (BVP) sensors, widely integrated into commercially available wearable devices, offer a cost-effective and convenient solution for stress detection, but existing methods face challenges such as data imbalance, complex models unsuitable for real-time use, and limited generalizability. This study presents a lightweight residual-encoder and transformer-encoders network (ReTeNet) for stress monitoring using BVP signals. The proposed model is trained and evaluated on two datasets using a subject-independent, leave-one-subject-out (LOSO) cross-validation strategy: the private RUET SPML dataset with 26 healthy subjects and the publicly available WESAD dataset with 15 healthy subjects. It achieves 93.59% accuracy, 95.60% F1-score, and 0.9569 AUC on the RUET SPML dataset, while attaining 98.23% accuracy, 97.58% F1-score, and 0.9953 AUC on the WESAD dataset. The model effectively distinguishes mental stress with high accuracy while maintaining a lightweight architecture, making it well-suited for wearable devices. Furthermore, its capability to maintain balanced performance across imbalanced datasets highlights its potential for reliable real-time stress monitoring.

Förderung

  • University Grants Commission, Bangladesh, and Rajshahi University of Engineering & Technology

Zitieren

APA

Ali, M. S., Motin, M. A., & Kabir, S. (2025). ReTeNet: A Residual Encoder and Transformer Encoders Network for Stress Monitoring From Wearable Device. IEEE Signal Processing Letters, 32, 3635-3639. https://doi.org/10.1109/lsp.2025.3607767

Vancouver

Ali MS, Motin MA, Kabir S. ReTeNet: A Residual Encoder and Transformer Encoders Network for Stress Monitoring From Wearable Device. IEEE Signal Processing Letters. 2025;32:3635-3639. doi:10.1109/lsp.2025.3607767

BibTeX
@article{Ali2025,
  author = {Ali, Md Santo and Motin, Mohammod Abdul and Kabir, Sumaiya},
  title = {ReTeNet: A Residual Encoder and Transformer Encoders Network for Stress Monitoring From Wearable Device},
  journal = {IEEE Signal Processing Letters},
  year = {2025},
  volume = {32},
  pages = {3635--3639},
  doi = {10.1109/lsp.2025.3607767}
}
Kostenlos starten →