EUVIMEDEUVIMED entdecken
Crossref

A Novel DNN-Based Semi-Parametric Calibration Method for Parallel Robots Considering Non-Kinematic Parameters

Shuai Fan, Ye Liang, Yudong Wang, Lisi Geng, Cheng Zeng, Shaohui Feng, Rui Huang

IEEE Robotics and Automation Letters · 2026-05 · 11 (5) · 5654-5661

DOI: 10.1109/lra.2026.3673938 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Robotics and Automation Letters, 2026-05. Verfasst von Shuai Fan und 6 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Research and Development Program of the Science and Technology Bureau of Chengdu, Research Foundation of Chengdu University of Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The pointing accuracy of pose adjusting parallel robots (PAPRs) is critical for the imaging quality of Cherenkov telescopes, making kinematic calibration crucial for improvement. However, non-geometric error sources like elastic deformation and joint clearances create an inevitable difference between theoretical and actual kinematic models, restricting accuracy. While various calibration methods exist, models considering non-kinematic nonlinear parameters are often highly complex and involve stringent measurement requirements. To achieve efficient, stable, and high-precision calibration, this paper proposes a novel deep neural network (DNN)-based semi-parametric model calibration method, combined with a Light-Spot-Mapping Kinematic Model (LKM). This approach enables high-precision matching between the theoretical and actual robot models through the semi-parametric framework, enhancing calibration performance. It also utilizes a high-precision camera as the measurement device, effectively reducing calibration time and labor costs. An experiment on a PS+PSS+PSR-type PAPR demonstrated that the pointing accuracy was improved by 47.7% after geometric parameter calibration, and by 81.2% (relative to the uncalibrated state) after non-geometric parameter calibration, achieving a final absolute accuracy of 156 ${\mu rad}$. The proposed method is effective for improving the accuracy of PAPRs while accounting for the influence of nonlinear parameters.

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Program of the Science and Technology Bureau of Chengdu
  • Research Foundation of Chengdu University of Technology

Zitieren

APA

Fan, S., Liang, Y., Wang, Y., Geng, L., Zeng, C., Feng, S., & Huang, R. (2026). A Novel DNN-Based Semi-Parametric Calibration Method for Parallel Robots Considering Non-Kinematic Parameters. IEEE Robotics and Automation Letters, 11(5), 5654-5661. https://doi.org/10.1109/lra.2026.3673938

Vancouver

Fan S, Liang Y, Wang Y, Geng L, Zeng C, Feng S, et al. A Novel DNN-Based Semi-Parametric Calibration Method for Parallel Robots Considering Non-Kinematic Parameters. IEEE Robotics and Automation Letters. 2026;11(5):5654-5661. doi:10.1109/lra.2026.3673938

BibTeX
@article{Fan2026,
  author = {Fan, Shuai and Liang, Ye and Wang, Yudong and Geng, Lisi and Zeng, Cheng and Feng, Shaohui and Huang, Rui},
  title = {A Novel DNN-Based Semi-Parametric Calibration Method for Parallel Robots Considering Non-Kinematic Parameters},
  journal = {IEEE Robotics and Automation Letters},
  year = {2026},
  volume = {11},
  number = {5},
  pages = {5654--5661},
  doi = {10.1109/lra.2026.3673938}
}
Kostenlos starten →