EUVIMEDEUVIMED entdecken
Crossref

A Valve-Less Electro-Hydrostatic Powered Prosthetic Foot to Improve the Power Efficiency During Walking

Bowen Li, Xin Li, Hongguang Xu, Qitao Huang

IEEE Robotics and Automation Letters · 2026-04 · 11 (4) · 4833-4840

DOI: 10.1109/lra.2026.3668985 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Robotics and Automation Letters, 2026-04. Verfasst von Bowen Li und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hydraulic systems have been widely applied in lower-limb prostheses, primarily for their compact actuation and inherent damping capability. However, when applied to powered prosthetic feet, valves and other damping elements cause unavoidable energy dissipation, thereby constraining their power density. To address this limitation, we propose a valve-less electro-hydrostatic powered prosthetic foot aimed at enhancing power efficiency. In addition, a gas accumulator’s nonlinear elasticity is considered, forming a hydraulic series elastic actuator with passive stiffness comparable to the human ankle during walking. This configuration lowers the motor’s required speed, consequently reducing its actual electrical power. The proposed design was evaluated through a treadmill walking experiment with a non-impaired subject walking at 1.1 m/s. The results showed that the prosthetic foot provided sufficient positive power relative to human reference values. Moreover, the prosthesis achieved a peak output power of 206.3 $\pm$ 15.0 W, while the corresponding motor electrical power was only 147.5 $\pm$ 29.5 W. Our study demonstrates that the electro-hydrostatic system holds significant potential for enhancing the power density of powered prosthetic feet.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Li, B., Li, X., Xu, H., & Huang, Q. (2026). A Valve-Less Electro-Hydrostatic Powered Prosthetic Foot to Improve the Power Efficiency During Walking. IEEE Robotics and Automation Letters, 11(4), 4833-4840. https://doi.org/10.1109/lra.2026.3668985

Vancouver

Li B, Li X, Xu H, Huang Q. A Valve-Less Electro-Hydrostatic Powered Prosthetic Foot to Improve the Power Efficiency During Walking. IEEE Robotics and Automation Letters. 2026;11(4):4833-4840. doi:10.1109/lra.2026.3668985

BibTeX
@article{Li2026,
  author = {Li, Bowen and Li, Xin and Xu, Hongguang and Huang, Qitao},
  title = {A Valve-Less Electro-Hydrostatic Powered Prosthetic Foot to Improve the Power Efficiency During Walking},
  journal = {IEEE Robotics and Automation Letters},
  year = {2026},
  volume = {11},
  number = {4},
  pages = {4833--4840},
  doi = {10.1109/lra.2026.3668985}
}