High-Precision Intracavity Torsion Sensing Based on a Polarization-Maintaining-Fiber Lyot Filter
IEEE Photonics Technology Letters · 2026-12 · 38 (24) · 2097-2100
DOI: 10.1109/lpt.2026.3748220 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Photonics Technology Letters, 2026-12. Verfasst von Zhiyu Zhang und 4 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia Autonomous Region of China.
Abstract (Originalsprache)
We propose and experimentally demonstrate a wavelength-modulated intracavity torsion sensor based on a polarization-maintaining-fiber (PMF) Lyot filter. Analysis of the filter’s transmission characteristics reveals that variation in the torsion-induced birefringence in the PMF leads to a red shift of the filter transmission spectrum. Based on simulation results, we selected an optimal PMF length of 18 cm to achieve high torsion sensitivity. To enhance wavelength-interrogation accuracy and suppress phase-induced wavelength ambiguity, we incorporated the Lyot filter into an erbium–ytterbium co-doped-fiber ring-laser cavity, forming an intracavity sensing configuration. Compared with the conventional passive scheme, the proposed structure compensates for cavity loss and provides stable wavelength tracking. Experimentally, wavelength sensitivities of 33.2 and 35.3 picometers per degree (pm/°) were obtained within two linear-response regions, with a signal-to-noise ratio exceeding 22 dB. Moreover, torsion-measurement accuracy improves from 10.74° to 0.06°. The proposed configuration offers a compact and high-precision solution for torsion-sensing applications.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Inner Mongolia Autonomous Region of China
Zitieren
APA
Zhang, Z., Bai, X., Han, X., Cheng, S., & Liu, Y. (2026). High-Precision Intracavity Torsion Sensing Based on a Polarization-Maintaining-Fiber Lyot Filter. IEEE Photonics Technology Letters, 38(24), 2097-2100. https://doi.org/10.1109/lpt.2026.3748220
Vancouver
Zhang Z, Bai X, Han X, Cheng S, Liu Y. High-Precision Intracavity Torsion Sensing Based on a Polarization-Maintaining-Fiber Lyot Filter. IEEE Photonics Technology Letters. 2026;38(24):2097-2100. doi:10.1109/lpt.2026.3748220
BibTeX
@article{Zhang2026,
author = {Zhang, Zhiyu and Bai, Xiaolei and Han, Xiaoran and Cheng, Si and Liu, Yiyao},
title = {High-Precision Intracavity Torsion Sensing Based on a Polarization-Maintaining-Fiber Lyot Filter},
journal = {IEEE Photonics Technology Letters},
year = {2026},
volume = {38},
number = {24},
pages = {2097--2100},
doi = {10.1109/lpt.2026.3748220}
}