EUVIMEDEUVIMED entdecken
Crossref

Assumption-Free Active Calibration of mm-Wave Phased Arrays Using Excitation Estimation via Far-Field Measurements

Mohammad Abdollah Chalaki, Ahmed Ben Ayed, Patrick Mitran, Slim Boumaiza

IEEE Microwave and Wireless Technology Letters · 2026-06 · 36 (6) · 938-941

DOI: 10.1109/lmwt.2026.3678018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Microwave and Wireless Technology Letters, 2026-06. Verfasst von Mohammad Abdollah Chalaki und 3 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada and in part by Ontario Research Funds-Research Excellence.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This letter proposes an active calibration method for millimeter-wave (mm-Wave) beamforming arrays that estimates the complex excitation of each element under realistic operating conditions. The method leverages a sequence of far-field transmission coefficient measurements collected while the array is rotated toward different angles. From these measurements, the complex excitation at each element is estimated without imposing any assumptions on the beamforming circuitry behavior. With all elements active during measurements, the estimated excitations inherently capture effects of mutual coupling and loading, which traditional elementwise calibration fails to account for. The method is validated on a $4{\,}\times {\,}4$ phased array operating at 38.5 GHz. Radiation patterns reconstructed from the estimated excitations match the measured patterns with a normalized root-mean-square error (NRMSE) better than −30 dB, confirming that the estimated excitations closely represent the true active-array behavior. In contrast, reconstructing the pattern using excitations obtained from elementwise measurements yields an NRMSE of only −8 dB. Furthermore, when beamforming toward boresight, the proposed active calibration method improves the measured boresight gain by 1.4 dB relative to passive calibration and reduces sidelobe-level imbalance by 2.4 dB. Finally, when the proposed method is applied for boresight null-steering, it achieves a null-depth that is 21.2 dB deeper than that obtained from passive calibration.

Förderung

  • Natural Sciences and Engineering Research Council of Canada and in part by Ontario Research Funds-Research Excellence

Zitieren

APA

Chalaki, M. A., Ayed, A. B., Mitran, P., & Boumaiza, S. (2026). Assumption-Free Active Calibration of mm-Wave Phased Arrays Using Excitation Estimation via Far-Field Measurements. IEEE Microwave and Wireless Technology Letters, 36(6), 938-941. https://doi.org/10.1109/lmwt.2026.3678018

Vancouver

Chalaki MA, Ayed AB, Mitran P, Boumaiza S. Assumption-Free Active Calibration of mm-Wave Phased Arrays Using Excitation Estimation via Far-Field Measurements. IEEE Microwave and Wireless Technology Letters. 2026;36(6):938-941. doi:10.1109/lmwt.2026.3678018

BibTeX
@article{Chalaki2026,
  author = {Chalaki, Mohammad Abdollah and Ayed, Ahmed Ben and Mitran, Patrick and Boumaiza, Slim},
  title = {Assumption-Free Active Calibration of mm-Wave Phased Arrays Using Excitation Estimation via Far-Field Measurements},
  journal = {IEEE Microwave and Wireless Technology Letters},
  year = {2026},
  volume = {36},
  number = {6},
  pages = {938--941},
  doi = {10.1109/lmwt.2026.3678018}
}
Kostenlos starten →