Automated Evaluation of Urodynamic Examinations Through Local Linear Models: Validation on Spinal Cord Injury Individuals

Wensi Zhang iD, Jurgen Pannek, Jens Wollner iD, Robert Riener iD, Diego Paez-Granados iD

IEEE Journal of Translational Engineering in Health and Medicine · 2025

DOI: 10.1109/jtehm.2025.3544486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Translational Engineering in Health and Medicine, 2025. Verfasst von Wensi Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Spinal Cord Injury & Artificial Intelligence (SCAI) Laboratory, D-HESTETH Zürich 8092 Zürich Switzerland. Hauptthemen laut MEDLINE: Spinal Cord Injuries, Urodynamics, Urinary Bladder, Overactive. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Schweizer Paraplegiker Stiftung, ETH Zürich Foundation through the Digital Transformation in Personalized Healthcare for SCI Individuals.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Investigating consistent methods and metrics for classifying Detrusor Overactivity (DO) events and developing an automated robust method for clinical measurements calculation from cystometry data in persons with spinal cord injury (SCI). METHODS AND PROCEDURES: A two-stage method for was proposed to detect DO events. In the first stage, DO peaks were detected using local linear models combined with thresholding criteria derived from clinical definitions and known artifacts. In the second stage, a segmentation method was proposed to detect the start and end time points of each DO event, marking the DO activity periods. As a result, complete clinical measurements, including bladder compliance, can be estimated automatically. The method was developed and tested on 77 anonymized urodynamic samples from SCI individuals (40 DO-positive, 37 DO-negative) with 158 annotated DO events. RESULTS: On test data, in terms of the patient-level diagnosis of DO, the proposed method achieved an accuracy of 100%. Individual DO event detection achieved an average precision of 0.94 and recall of 0.72. Detrusor activity period identification showed a precision of 0.86 and a recall of 0.88. The task of automated bladder compliance estimation showed that the point-value-based method yields a lower median absolute error (MAE) compared to the proposed line-fitting-based method, with a MAE of 5.20 and 7.14 ml/cmH2O, respectively. Finally, for classifying bladder function into normal, low and severely low compliance, the proposed method had an accuracy of 88%. CONCLUSION: Our proposed local model fitting with thresholding based on clinical knowledge, achieved accurate automated results for cytometry data, which will enable objective assessment of routinely performed examinations. Clinical and Translational Impact Statement- This work proposes a fully automated detrusor overactivity diagnosis and feature extraction method. Empowering medical teams to consistently assess urodynamic studies while aiding disease characterization and enhancing clinical decision-making for SCI patients. Furthermore, it provides a mathematically defined method for extending the pipeline to other populations and standardizing clinical assessments.Category: Clinical Engineering, Medical Devices and Systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal Cord InjuriesUrodynamicsUrinary Bladder, OveractiveHumansFemaleMaleAdultLinear ModelsMiddle AgedUrinary BladderYoung AdultAlgorithms

Stichwörter der Autor:innen

Urodynamicsautonomous linear state-space modelcystometrydetrusor overactivityspinal cord injury

Autor:innen und Institutionen

  • Spinal Cord Injury & Artificial Intelligence (SCAI) Laboratory, D-HESTETH Zürich 8092 Zürich Switzerland.
  • Swiss Paraplegic Research (SPF) 6207 Nottwil Switzerland.
  • Swiss Paraplegic Zentrum (SPZ) 6207 Nottwil Switzerland.
  • University Hospital Balgrist 8092 Zürich Switzerland.

ORCID-Profile: Wensi Zhang, Jens Wollner, Robert Riener, Diego Paez-Granados

Förderung

  • Schweizer Paraplegiker Stiftung
  • ETH Zürich Foundation through the Digital Transformation in Personalized Healthcare for SCI Individuals

Zitieren

APA

Zhang, W., Pannek, J., Wollner, J., Riener, R., & Paez-Granados, D. (2025). Automated Evaluation of Urodynamic Examinations Through Local Linear Models: Validation on Spinal Cord Injury Individuals. IEEE Journal of Translational Engineering in Health and Medicine. https://doi.org/10.1109/jtehm.2025.3544486

Vancouver

Zhang W, Pannek J, Wollner J, Riener R, Paez-Granados D. Automated Evaluation of Urodynamic Examinations Through Local Linear Models: Validation on Spinal Cord Injury Individuals. IEEE Journal of Translational Engineering in Health and Medicine. 2025. doi:10.1109/jtehm.2025.3544486

BibTeX
@article{Zhang2025,
  author = {Zhang, Wensi and Pannek, Jurgen and Wollner, Jens and Riener, Robert and Paez-Granados, Diego},
  title = {Automated Evaluation of Urodynamic Examinations Through Local Linear Models: Validation on Spinal Cord Injury Individuals},
  journal = {IEEE Journal of Translational Engineering in Health and Medicine},
  year = {2025},
  doi = {10.1109/jtehm.2025.3544486}
}
Kostenlos starten →