EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Non-Contact Monitoring of Inhalation-Exhalation (I:E) Ratio in Non-Ventilated Subjects

Paul S Addison iD, Andre Antunes iD, Dean Montgomery iD, Ulf R Borg

IEEE Journal of Translational Engineering in Health and Medicine · 2024

DOI: 10.1109/jtehm.2024.3496196 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Translational Engineering in Health and Medicine, 2024. Verfasst von Paul S Addison und 3 weiteren Autor:innen. Beteiligte Einrichtung: Acute Care and Monitoring, Medtronic Edinburgh Scotland U.K. Hauptthemen laut MEDLINE: Exhalation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The inhalation-exhalation (I:E) ratio, known to be an indicator of respiratory disease, is the ratio between the inhalation phase and exhalation phase of each breath. Here, we report on results from a non-contact monitoring method for the determination of the I:E ratio. This employs a depth sensing camera system that requires no sensors to be physically attached to the patient. A range of I:E ratios from 0.3 to 1.0 over a range of respiratory rates from 4 to 40 breaths/min were generated by healthy volunteers, producing a total of 3,882 separate breaths for analysis. Depth information was acquired using an Intel D415 RealSense camera placed at 1.1 m from the subjects' torso. This data was processed in real-time to extract depth changes within the subjects' torso region corresponding to respiratory activity. This was further converted into a respiratory signal from which the I:E ratio was determined (I:E[Formula: see text]). I:Edepth was compared to spirometer data (I:E[Formula: see text]). A Bland Altman analysis produced a mean bias of -0.004, with limits of agreement [-0.234, 0.227]. A linear regression analysis produced a line of best fit given by I:E[Formula: see text] I:Espiro - 0.006, with 95% confidence intervals for the slope [0.988, 1.019] and intercept [-0.017, 0.004]. We have demonstrated the viability of a non-contact monitoring method for determining the I:E ratio on healthy subjects breathing without mechanical support. This measure may be useful in monitoring the deterioration in respiratory status and/or response to therapy within the patient population. Clinical and Translational Impact Statement - The I:E ratio is an indicator of disease severity in COPD and asthma. Non-contact continuous monitoring of I:E ratio will offer the clinician a powerful new tool for respiratory monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ExhalationHumansMaleAdultFemaleMonitoring, PhysiologicSignal Processing, Computer-AssistedYoung AdultInhalationMiddle Aged

Stichwörter der Autor:innen

Inhalation-exhalation ratiodepth sensing cameranon-contact monitoringrespiratory disease

Autor:innen und Institutionen

  • Acute Care and Monitoring, Medtronic Edinburgh Scotland U.K.
  • Acute Care and Monitoring, Medtronic Boulder CO USA.

ORCID-Profile: Paul S Addison, Andre Antunes, Dean Montgomery

Zitieren

APA

Addison, P. S., Antunes, A., Montgomery, D., & Borg, U. R. (2024). Non-Contact Monitoring of Inhalation-Exhalation (I:E) Ratio in Non-Ventilated Subjects. IEEE Journal of Translational Engineering in Health and Medicine. https://doi.org/10.1109/jtehm.2024.3496196

Vancouver

Addison PS, Antunes A, Montgomery D, Borg UR. Non-Contact Monitoring of Inhalation-Exhalation (I:E) Ratio in Non-Ventilated Subjects. IEEE Journal of Translational Engineering in Health and Medicine. 2024. doi:10.1109/jtehm.2024.3496196

BibTeX
@article{Addison2024,
  author = {Addison, Paul S and Antunes, Andre and Montgomery, Dean and Borg, Ulf R},
  title = {Non-Contact Monitoring of Inhalation-Exhalation (I:E) Ratio in Non-Ventilated Subjects},
  journal = {IEEE Journal of Translational Engineering in Health and Medicine},
  year = {2024},
  doi = {10.1109/jtehm.2024.3496196}
}
Kostenlos starten →